Standard Practice for Open-Path Fourier Transform Infrared (OP/FT-IR) Monitoring of Gases and Vapors in Air
Automaticky přeložený název:
Standardní praktiky pro Open- Path Fourier Transform Infrared ( OP / FT - IR ) monitorování plynů a par v ovzduší
NORMA vydána dne 1.12.2007
Označení normy: ASTM E1982-98(2007)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.12.2007
Kód zboží: NS-43833
Počet stran: 17
Přibližná hmotnost: 51 g (0.11 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
air analysis, Fourier transform infrared, FT-IR, open-path monitoring, spectrometers, ICS Number Code 17.180.30 (Optical measuring instruments)
Significance and Use | ||||||||||||
An OP/FT-IR monitor can, in principle, measure the concentrations of all IR-active gases and vapors in the atmosphere. Detailed descriptions of OP/FT-IR systems and the fundamental aspects of their operation are given in Guide E 1865 and the FT-IR Open-Path Monitoring Guidance Document. A method for processing OP/FT-IR data to obtain the concentrations of gases over a long, open path is given in Compendium Method TO-16. Applications of OP/FT-IR systems include monitoring for gases and vapors in ambient air, along the perimeter of an industrial facility, at hazardous waste sites and landfills, in response to accidental chemical spills or releases, and in workplace environments. |
||||||||||||
1. Scope | ||||||||||||
1.1 This practice covers procedures for using active open-path
Fourier transform infrared (OP/FT-IR) monitors to measure the
concentrations of gases and vapors in air. Procedures for choosing
the instrumental parameters, initially operating the instrument,
addressing logistical concerns, making ancillary measurements,
selecting the monitoring path, acquiring data, analyzing the data,
and performing quality control on the data are given. Because the
logistics and data quality objectives of each OP/FT-IR monitoring
program will be unique, standardized procedures for measuring the
concentrations of specific gases are not explicitly set forth in
this practice. Instead, general procedures that are applicable to
all IR-active gases and vapors are described. These procedures can
be used to develop standard operating procedures for specific
OP/FT-IR monitoring applications.
1.2 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||