Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature
Přeložit název
NORMA vydána dne 1.2.2023
Označení normy: ASTM E1965-98(2023)
Datum vydání normy: 1.2.2023
Kód zboží: NS-1102539
Počet stran: 17
Přibližná hmotnost: 51 g (0.11 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
This specification covers infrared thermometers, which are electronic instruments intended for the intermittent measurement and monitoring of patient temperatures by means of detecting the intensity of thermal radiation between the subject of measurement and the sensor. The specification addresses the assessment of the subject´s internal body temperature through measurement of thermal emission from the ear canal. Though, performance requirements for noncontact temperature measurement of skin are also provided. Limits are set for laboratory accuracy, and determination and disclosure of clinical accuracy of the covered instruments are required. Performance and storage limits under various environmental conditions, requirements for labeling, and test procedures are all established herein.
Keywords:
auditory canal, body temperature, ear, fever, infrared, medical instrument, temperature, thermometer, tympanic membrane,, ICS Number Code 17.040.20 (Properties of surfaces)
1. Scope | ||||||||||||||||
1.1?This specification covers electronic instruments intended for intermittent measuring and monitoring of patient temperatures by means of detecting the intensity of thermal radiation between the subject of measurement and the sensor. 1.2?The specification addresses assessing subjects body internal temperature through measurement of thermal emission from the ear canal. Performance requirements for noncontact temperature measurement of skin are also provided. 1.3?The specification sets limits for laboratory accuracy and requires determination and disclosure of clinical accuracy of the covered instruments. 1.4?Performance and storage limits under various environmental conditions, requirements for labeling, and test procedures are established. Note 1:?For electrical safety, consult Underwriters Laboratory
Standards.Note 2:?For electromagnetic emission requirements and tests,
refer to CISPR 11: 1990 Lists of Methods of Measurement of
Electromagnetic Disturbance Characteristics of Industrial,
Scientific, and Medical (ISM) Radiofrequency Equipment.3
1.5?The values of quantities stated in SI units are to be regarded as the standard. The values of quantities in parentheses are not in SI and are optional. 1.6?The following precautionary caveat pertains only to the test method portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.