Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves
Automaticky přeložený název:
Standardní zkušební metoda pro gravimetrickém stanovení energeticky nezávislé, zbytek z Cleanroom rukavice
NORMA vydána dne 1.5.2011
Označení normy: ASTM E1731-11
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2011
Kód zboží: NS-42809
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Ostatní materiály pro letectví a kosmické dopravní prostředky
Fyzikálně chemické analytické metody
Keywords:
cleanroom gloves, gloves, non-volatile residue, NVR, Cleanrooms (materials/applications), Gloves, Gravimetric determination, Nonvolatile residue (NVR), Residue, ICS Number Code 49.025.99 (Other materials), 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||||||||||||
The NVR obtained by this test method is that amount which is available for release by the gloves onto handled surfaces. Evaporation of solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between room temperature and the test temperature is not likely to result in significant variances. This method may be more aggressive than necessary to determine the suitability of cleanroom gloves that are restricted to dry operations only. Various other methods exist for determining NVR, for example Practice G120 and IES-RP-CC005. This test is not intended to replace test methods used for other purposes. |
||||||||||||
1. Scope | ||||||||||||
1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Historická
1.7.2010
Historická
1.10.2009
Historická
1.5.2010
Historická
1.5.2014
Historická
1.12.2011
Historická
1.11.2008
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.