Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Testing Variable-Wavelength Photometric Detectors Used in Liquid Chromatography
Automaticky přeložený název:
Standardní postup zkoušení nastavitelnou vlnovou délkou fotometrických detektory Používá se v kapalinové chromatografie
NORMA vydána dne 1.11.2011
Označení normy: ASTM E1657-98(2011)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2011
Kód zboží: NS-42541
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
linearity, noise measurement, photometric detector, variable wavelength, wavelength accuracy , Drift, Linear changes/linearity, Liquid chromatography (LC), Long-term noise, Noise level measurement, Photometric detectors, Short-term noise, Variable-wavelength photometric detectors, VWPD (variable-wavelength photometric detectors), Wavelength accuracy, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||
Although it is possible to observe and measure each of the several characteristics of a detector under different and unique conditions, it is the intent of this practice that a complete set of detector specifications should be obtained under the same operating conditions. It should also be noted that to completely specify a detector's capability, its performance should be measured at several sets of conditions within the useful range of the detector. The terms and tests described in this practice are sufficiently general that they may be used regardless of the ultimate operating parameters. Linearity and response time of the recorder or other readout device used should be such that they do not distort or otherwise interfere with the performance of the detector. This requires adjusting the gain, damping, and calibration in accordance with the manufacturer's directions. If additional electronic filters or amplifiers are used between the detector and the final readout device, their characteristics should also first be established. |
||
1. Scope | ||
1.1 This practice covers the testing of the performance of a variable-wavelength photometric detector (VWPD) used as the detection component of a liquid-chromatographic (LC) system operating at one or more wavelengths in the range 190 to 800 nm. Many of the measurements are made at 254 nm for consistency with Practice E685. Measurements at other wavelengths are optional. 1.2 This practice is intended to describe the performance of the detector both independently of the chromatographic system (static conditions) and with flowing solvent (dynamic conditions). 1.3 For general liquid chromatographic procedures, consult Refs (1-9). 1.4 For general information concerning the principles, construction, operation, and evaluation of liquid-chromatography detectors, see Refs (10, 11) in addition to the sections devoted to detectors in Refs (1-7). 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Historická
1.5.2014
Historická
1.12.2009
Historická
1.2.2014
Historická
1.11.2011
Historická
1.5.2014
Historická
1.7.2013
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 17.07.2024 (Počet položek: 2 336 011)
© Copyright 2024 NORMSERVIS s.r.o.