Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover (Includes all amendments And changes 7/3/2019).
Automaticky přeložený název:
Standardní zkušební metody pro vodní páru zpomalovače použít ve styku se Zemí Pod betonovými deskami, na stěny, nebo jako kryt země
NORMA vydána dne 1.4.2013
Označení normy: ASTM E154/E154M-08a(2013)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2013
Kód zboží: NS-42116
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
earth covers, flame-spread resistance, low-temperature flexibility, plastic-flow resistance, puncture-resistance testing, soil contact testing, tensile testing, ultraviolet light resistance, water-vapor retarder, water-vapor transmission testing, ICS Number Code 91.100.30 (Concrete and concrete products)
Significance and Use | ||||||||||||||||||||||||||||
4.1 In service, vapor retarders may be exposed to a variety of conditions, so no one test will provide evaluations related to performance for all exposures (refer to Guide E241 and Practice C755). Neither will all test methods listed be necessary in all evaluations for specific exposures (see 4.2 Limitations—Prior to use and in service, vapor retarders may be exposed to a variety of conditions so no one test will provide evaluations related to performance for all exposures (refer to Guide E241 and Practice C755). Neither will all tests be necessary in all evaluations for specific exposures. Consequently, the tests and required test results shall be agreed upon by the purchaser and the supplier (see 1.1 These test methods2 cover the determination of the properties of flexible membranes to be used as vapor retarders in contact with earth under concrete slabs, against walls, or as ground cover in crawl spaces. The test methods are applicable primarily to plastic films and other flexible sheets. The materials are not intended to be subjected to sustained hydrostatic pressure. The procedures simulate conditions to which vapor retarders may be subjected prior to and during installation, and in service. 1.2 The test methods included
are:
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|
Historická
1.6.2014
Historická
1.10.2009
Historická
1.2.2013
Historická
1.6.2008
Historická
15.4.2012
Historická
15.12.2011
Poslední aktualizace: 20.07.2024 (Počet položek: 2 338 064)