Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover
Automaticky přeložený název:
Standardní zkušební metody pro vodní páry zpomalovače použít ve styku se Zemí Pod betonové desky, na stěnách , nebo jako půdopokryvná
NORMA vydána dne 15.3.2008
Označení normy: ASTM E154-08
Poznámka: NEPLATNÁ
Datum vydání normy: 15.3.2008
Kód zboží: NS-42112
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
earth covers, flame-spread resistance, low-temperature flexibility, plastic-flow resistance, puncture-resistance testing, soil contact testing, tensile testing, ultraviolet light resistance, water-vapor retarder, water-vapor transmission testing, Microbiological examination--paints/related coatings, Temperature tests--building materials, Tensile properties/testing--building materials/applications, Admixtures (soil), Concrete construction materials/applications, Concrete slabs, Crawl spaces
Significance and Use | ||||||||||||||||||||||||||||
In service, vapor retarders may be exposed to a variety of conditions, so no one test will provide evaluations related to performance for all exposures (refer to Guide E 241 and Practice C 755). Neither will all test methods listed be necessary in all evaluations for specific exposures (see 16.2). Limitations—Prior to use and in service, vapor retarders may be exposed to a variety of conditions so no one test will provide evaluations related to performance for all exposures (refer to Guide E 241 and Practice C 755). Neither will all tests be necessary in all evaluations for specific exposures. Consequently, the tests and required test results shall be agreed upon by the purchaser and the supplier (see 16.2). |
||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||
1.1 These test methods cover the determination of the properties of flexible membranes to be used as vapor retarders in contact with earth under concrete slabs, against walls, or as ground cover in crawl spaces. The test methods are applicable primarily to plastic films and other flexible sheets. The materials are not intended to be subjected to sustained hydrostatic pressure. The procedures simulate conditions to which vapor retarders may be subjected prior to and during installation, and in service. 1.2 The test methods included are:
1.3 The values stated in acceptable metric units shall be considered standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|