Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Guide for Designing Biological Tests with Sediments
Přeložit název
NORMA vydána dne 1.1.2023
Označení normy: ASTM E1525-02(2023)
Datum vydání normy: 1.1.2023
Kód zboží: NS-1136291
Počet stran: 25
Přibližná hmotnost: 75 g (0.17 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
bioaccumulation, contamination, experimental design, freshwater, saltwater, sediment, toxicity ,, ICS Number Code 13.080.30 (Biological properties of soil)
Significance and Use | ||||||||||||||||||||||||||||||
6.1?Contaminated sediments may affect natural populations of aquatic organisms adversely. Sediment-dwelling organisms may be exposed directly to contaminants by the ingestion of sediments and by the uptake of sediment-associated contaminants from interstitial and overlying water. Contaminated sediments may affect water column species directly by serving as a source of contaminants to overlying waters or a sink for contaminants from overlying waters. Organisms may also be affected when contaminated sediments are suspended in the water column by natural or human activities. Water column species and nonaquatic species may also be affected indirectly by contaminated sediments by the transfer of contaminants through ecosystems 6.2?The procedures described in this guide may be used and adapted for incorporation in basic and applied research to determine the ecological effects of contaminated sediments. These same methods may also be used in the development and implementation of monitoring and regulatory programs designed to prevent and manage sediment contamination. 6.3?Sediment tests with aquatic organisms can be used to quantify the acute and chronic toxicity and the bioavailability of new and presently used materials. Sediment toxicity may also result from environmental processes such as ammonia generation, pH shifts, or dissolved oxygen fluctuation. In many cases, consideration of the adverse effects of sediment-associated contaminants is only one part of a complete hazard assessment of manufactured compounds that are applied directly to the environment (for example, pesticides) and those released (for example, through wastewater effluents) as by-products from the manufacturing process or from municipalities (7). 6.4?Sediment tests can be used to develop exposure-response relationships for individual toxicants by spiking clean sediments with varying concentrations of a test chemical and determining the concentration that elicits the target response in the test organism (Guide E1391). Sediment tests can also be designed to determine the effects that the physical and chemical properties of sediments have on the bioavailability and toxicity of compounds. 6.5?Sediment tests can provide valuable information for making decisions regarding the management of contaminated sediments from hazardous waste sites and other contaminated areas. Biological tests with sediments can also be used to make defensible management decisions on the dredging and disposal of potentially contaminated sediments from rivers and harbors. (1.1?As the contamination of freshwater and saltwater ecosystems continues to be reduced through the implementation of regulations governing both point and non-point source discharges, there is a growing emphasis and concern regarding historical inputs and their influence on water and sediment quality. Many locations in urban areas exhibit significant sediment contamination, which poses a continual and long-term threat to the functional condition of benthic communities and other species inhabiting these areas 1.2?Biological tests with sediments are an efficient means for evaluating sediment contamination because they provide information complementary to chemical characterizations and ecological surveys 1.3?This guide is arranged as follows:
1.4?The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 01.11.2024 (Počet položek: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.