Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Guide for Acousto-Ultrasonic Assessment of Composites, Laminates, and Bonded Joints
Automaticky přeložený název:
Standardní Průvodce pro akusticko - ultrazvukové posuzování kompozity , lamináty a lepených spojů
NORMA vydána dne 10.7.2002
Označení normy: ASTM E1495-02
Poznámka: NEPLATNÁ
Datum vydání normy: 10.7.2002
Kód zboží: NS-41960
Počet stran: 9
Přibližná hmotnost: 27 g (0.06 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
acoustic emission, acousto-ultrasonics, bonded joints, composites, laminates, materials characterization, mechanical properties assessment, nondestructive evaluation, nondestructive testing, stress wave factor, ultrasonic attenuation, ICS Number Code 19.100 (Non-destructive testing), 83.180 (Adhesives)
1. Scope | ||||||||
1.1 This guide explains the rationale and basic technology for the acousto-ultrasonic (AU) method. Guidelines are given for nondestructive evaluation (NDE) of flaws and physical characteristics that influence the mechanical properties and relative strength of composite structures (for example, filament-wound pressure vessels), adhesive bonds (for example, joints between metal plates), and interlaminar and fiber/matrix bonds in man-made composites and natural composites (for example, wood products). 1.2 This guide covers technical details and rules that must be observed to ensure reliable and reproducible quantitative AU assessments of laminates, composites, and bonded structures. The underlying principles, prototype apparatus, instrumentation, standardization, examination methods, and data analysis for such assessments are covered. Limitations of the AU method and guidelines for taking advantage of its capabilities are cited. 1.3 The objective of AU is to assess subtle flaws and associated strength variations in composite structures and bonded joints. Discontinuities such as large voids, disbonds, or extended lack of contact at interfaces can be assessed by other NDE methods such as conventional ultrasonics. 1.4 Additional information may be found in the publications cited in the list of references at the end of this guide. The referenced works provide background on research, applications, and various aspects of signal acquisition, processing, and interpretation. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)