Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Determining the Steady State Thermal Transmittance of Fenestration Systems
Automaticky přeložený název:
Standardní praxe pro stanovení ustáleného stavu součinitel prostupu tepla prosvětlovací systémy
NORMA vydána dne 10.10.1999
Označení normy: ASTM E1423-99
Poznámka: NEPLATNÁ
Datum vydání normy: 10.10.1999
Kód zboží: NS-41716
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Building constructions/materials-windows, Fenestration systems, Heat flux, Surface analysis-building constructions/materials, Thermal conductivity, Thermal transmission properties-steady-state, steady state thermal transmittance-fenestration systems, practice, ICS Number Code 91.060.50 (Doors and windows), 91.120.10 (Thermal insulation of buildings)
| 1. Scope | ||||||||||||||||||
|
1.1 This practice specifies standard test specimen sizes and test conditions, as well as the calculation and presentation of the thermal transmittance and conductance data measured in accordance with Test Method C1199. The standard sizes and conditions are to be used for fenestration product comparison purposes. The specifier may choose other sizes and conditions for product development or research purposes. 1.2 This practice refers to the thermal transmittance, , thermal conductance, , and the corresponding thermal resistances, u and Rc , respectively, of a fenestration system installed vertically in the absence of solar and air leakage effects. Note 1-To determine air leakage effects for windows and doors, Test Methods E283 and E1424 should be referenced. For solar effects, ANSI/ASHRAE Standard 74-1988 should be referenced.1.3 A discussion of the definitions and underlying assumptions for determining the thermal transmittance and thermal conductance is included. 1.4 This practice specifies the procedure for determining the standardized thermal transmittance using the experimentally determined thermal conductance, , and specified values of the room-side and weather-side surface conductances, I and hII , respectively. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||
|
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 05.04.2026 (Počet položek: 2 271 011)
© Copyright 2026 NORMSERVIS s.r.o.