Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Guide for Conduct of Micronucleus Assays in Mammalian Bone Marrow Erythrocytes (Withdrawn 2015)
Automaticky přeložený název:
Standardní Příručka pro chování mikronukleovém Testy v buňkách kostní dřeně savců erytrocytů (Withdrawn 2015 )
NORMA vydána dne 1.8.2008
Označení normy: ASTM E1263-97(2008)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.8.2008
Kód zboží: NS-41064
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Assay, Bone marrow nucleus assay, Chromosomal/genetic effects, Data analysis--environmental, Environmental control/fate, Environmental sampling/testing, Genetic examination, Mammalian in vivo bone marrow nucleus assay, Micronucleus assay, Statistical methods, Test animals, ICS Number Code 11.220 (Veterinary medicine)
Significance and Use |
This guide provides guidelines for the selection of animal species, dosage and sampling conditions, sampling and scoring methods, statistical design, and analysis of genotoxicity assays in which the endpoint measured is the frequency of micronucleated erythrocytes in mammalian bone marrow. |
1. Scope |
1.1 This guide provides recommended guidelines for performing the mammalian in vivo bone marrow micronucleus assay. Under appropriate test conditions, measurement of the frequency of newly formed micronucleated erythrocytes in bone marrow provides a convenient index of chromosomal damage in nucleated erythrocyte precursor cells. The rationale for the occurrence of micronuclei in conjunction with chromosomal damage has been described previously (1). This guide describes conditions under which the frequency of micronucleated erythrocytes in mammalian bone marrow is an appropriate measure of in vivo chromosomal damage, and provides guidelines for the design and technical execution of assays employing this endpoint. 1.2 The following guidelines for mammalian bone marrow erythrocyte micronucleus assays have been published by organizations concerned with the evaluation of genotoxicity test data. These references should be consulted for recommendations on details not covered in depth by this guide and for requirements of specific organizations or government agencies (2-6). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 15.11.2024 (Počet položek: 2 210 820)
© Copyright 2024 NORMSERVIS s.r.o.