Standard Guide for Selection and Calibration of Dosimetry Systems for Radiation Processing (Withdrawn 2002)
Automaticky přeložený název:
Standardní Průvodce pro výběr a kalibraci dozimetrie systémů pro radiační zpracování (Withdrawn 2002 )
NORMA vydána dne 10.3.2000
Označení normy: ASTM E1261-00
Poznámka: NEPLATNÁ
Datum vydání normy: 10.3.2000
Kód zboží: NS-41058
Počet stran: 13
Přibližná hmotnost: 39 g (0.09 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
absorbed dose, calibration facility, dose traceability, dosimeter, dosimetry system, electron beam, gamma ray, ionizing radiation, primary standard dosimeter, quality assurance, radiation processing, reference standard dosimeter, routine dosimeter, transfer standard dosimeter, ICS Number Code 17.240 (Radiation measurements)
| 1. Scope | ||||||||||||||||||||
|
1.1 This guide provides the basis for selecting and calibrating dosimetry systems used to measure absorbed dose in gamma-ray or X-ray fields and in electron beams used for radiation processing. It discusses the types of dosimetry systems that may be employed during calibration or on a routine basis as part of quality assurance in commercial radiation processing of products. This guide also discusses interpretation of absorbed dose and briefly outlines the uncertainties associated with the dosimetry measurements. The details of the calibration of the analytical instrumentation are addressed in individual dosimetry system standard practices. 1.2 The absorbed-dose range covered is from about 1 Gy (100 rad) to 1 MGy (100 Mrad). Source energies covered are from 0.1 to 50 MeV photons and electrons. 1.3 Standard practices and guides for specific dosimetry systems and applications are covered in other standards. Dosimetry for radiation processing with neutrons or heavy charged particles is not covered in this guide. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||