Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Determination of the Specimen Area Contributing to the Detected Signal in Auger Electron Spectrometers and Some X-Ray Photoelectron Spectrometers
Automaticky přeložený název:
Standardní praxe pro určování plochy vzoru přispívajících k Zjištěné signálu v Auger elektronové spektrometry a některé X - Ray Photoelectron spektrometry
NORMA vydána dne 10.4.2000
Označení normy: ASTM E1217-00
Poznámka: NEPLATNÁ
Datum vydání normy: 10.4.2000
Kód zboží: NS-40895
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Absorbed current, Computer programs, Current measurement, Deflection, Detectors, Line scan, Oscilloscope, Raster scan, Scanning, Signal detection, Specimen area, Spectrometry, Spectroscopy-auger electron (AES), Spectroscopy-x-ray photoelectron, Surface analysis-spectrochemical analysis, Topography, Voltage, Waveform, specimen area contributing to detected signal in, photoelectron/auger-electron spectroscopy, practice, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
| 1. Scope | ||||||
|
1.1 This practice describes methods for determining the specimen area contributing to the detected signal in X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) when this area is defined by the electron collection lens/aperture system. It is recommended as a useful means of determining the observed specimen area for different conditions of spectrometer operation, verifying adequate specimen alignment, and characterizing the imaging properties of the electron energy analyzer. 1.2 This practice is intended only for spectrometers in which the specimen area excited by X-ray or electron beams is or can be made larger than the specimen area viewed by the analyzer. It is assumed that, under normal conditions of operation, the specimen is excited by a beam of X rays or electrons that can be considered to have a uniform intensity over the specimen area viewed by the analyzer, and the specimen is homogeneous and uniform over the observed area. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
| 2. Referenced Documents | ||||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 22.04.2026 (Počet položek: 2 274 512)
© Copyright 2026 NORMSERVIS s.r.o.