Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians
Přeložit název
NORMA vydána dne 1.1.2023
Označení normy: ASTM E1192-23
Datum vydání normy: 1.1.2023
Kód zboží: NS-1102512
Počet stran: 15
Přibližná hmotnost: 45 g (0.10 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
This guide covers procedures for obtaining laboratory data concerning the adverse effects of aqueous ambient samples and effluents on certain species of freshwater and saltwater fishes, macroinvertebrates, and amphibians, during a short-term exposure, depending on the species, using the static, renewal, and flow-through techniques. These procedures will probably be useful for conducting acute toxicity tests on aqueous effluents with many other aquatic species, although modifications might be necessary. Static tests might not be applicable to effluents that have a high oxygen demand, or contain materials that (1) are highly volatile, (2) are rapidly biologically or chemically transformed in aqueous solutions, or (3) are removed from test solutions in substantial quantities by the test chambers or organisms during the test. Results of acute toxicity tests should usually be reported in terms of a median lethal concentration (LC50) or median effective concentration (EC50). An acute toxicity test does not provide information about whether delayed effects will occur. Specified requirements involving the following are detailed: (1) hazards; (2) apparatus: facilities, special requirements, construction materials, metering system, test chambers, cleaning, and acceptability; (3) dilution water requirements, source, treatment, and characterization; (4) effluent sampling point, collection, preservation, treatment, and test concentrations; (5) test organism species, age, source, care and handling, feeding, disease treatment, holding, acclimation, and quality; (6) procedure: experimental design, dissolved oxygen, temperature, loading, beginning the test, feeding, duration of test, biological data, and other measurements; (7) analytical methodology; (8) acceptability of test; (9) calculation of results; and (1) report of results.
Keywords:
acute toxicity, ambient samples, amphibians, EC50, effluents, freshwater fishes, freshwater invertebrates, LC50, saltwater fishes, saltwater invertebrates ,, ICS Number Code 13.060.70 (Examination of water for biological properties)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5.1?An acute effluent toxicity test is conducted to obtain information concerning the immediate effects on test organisms of a short-term exposure to an effluent under specific experimental conditions. One can directly examine acute effects of complex mixtures of chemicals as occurs in effluents and some ambient waters. Acute effluent toxicity tests can be used to evaluate the potential for designated-use or aquatic life impairment in the receiving stream, lake, or estuary. An acute toxicity test does not provide information about whether delayed effects will occur, although a post-exposure observation period, with appropriate feeding if necessary, might provide such information. 5.2?Results of acute effluent tests might be used to predict acute effects likely to occur on aquatic organisms in field situations as a result of exposure under comparable conditions, except that (1) motile organisms might avoid exposure when possible, (5.3?Results of acute effluent tests might be used to compare the acute sensitivities of different species and the acute toxicities of different effluents, and to study the effects of various environmental factors on results of such tests. 5.4?Acute tests are usually the first step in evaluating the effects of an effluent on aquatic organisms. 5.5?Results of acute effluent tests will depend on the temperature, composition of the dilution water, condition of the test organisms, exposure technique, and other factors. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1?This guide covers procedures for obtaining laboratory data concerning the adverse effects of an aqueous effluent on certain species of freshwater and saltwater fishes, macroinvertebrates, and amphibians, usually during 2 day to 4 day exposures, depending on the species, using the static, renewal, and flow-through techniques. These procedures will probably be useful for conducting acute toxicity tests on aqueous effluents with many other aquatic species, although modifications might be necessary. 1.2?Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of many other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting acute toxicity tests on aqueous effluents. 1.3?This guide is based in large part on Guide E729 where addition details are provided for test elements that may be applicable to the ambient and effluent toxicity testing described in this method. The major differences between the two guides are (1) the maximum test concentration is 100 % effluent or ambient sample, (2) testing is not chemical-specific, and (1.4?Selection of the technique to be used in a specific situation will depend upon the needs of the investigator and upon available resources. Static tests provide the most easily obtained measure of acute toxicity but should not last longer than 48 h. Renewal and flow-through tests may last longer than 48 h because the pH and concentrations of dissolved oxygen and effluent are maintained at desired levels and degradation and metabolic products are removed. Static tests might not be applicable to effluents that have a high oxygen demand or contain materials that (1.5?In the development of these procedures, an attempt was made to balance scientific and practical considerations and to ensure that the results will be sufficiently accurate and precise for the applications for which they are commonly used. A major consideration was that the common uses of the results of acute tests on effluents do not require or justify stricter requirements than those set forth in this guide. Although the tests may be improved by using more organisms, longer acclimation times, and so forth, the requirements presented in this guide should usually be sufficient. 1.6?Results of acute toxicity tests should usually be reported in terms of a median lethal concentration (LC50) or median effective concentration (EC50). In some situations, it might be necessary only to determine whether a specific concentration is acutely toxic to the test species or whether the LC50 or EC50 is above or below a specific concentration. 1.7?This guide is arranged as follows:
1.8?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.9?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||