Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Calibration of Silicon Non-Concentrator Photovoltaic Primary Reference Cells Under Global Irradiation (Withdrawn 2004)
Automaticky přeložený název:
Standardní zkušební metoda pro kalibraci Silicon Non- Concentrator Photovoltaic primární referenční buněk za globální ozáření (Withdrawn 2004 )
NORMA vydána dne 10.10.1999
Označení normy: ASTM E1039-99
Poznámka: NEPLATNÁ
Datum vydání normy: 10.10.1999
Kód zboží: NS-40223
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Calibration-nuclear analysis instrumentation, Characteristics/characterization, Current measurement-solar devices, Electrical performance-solar devices, Global irradiation, Irradiance/irradiation-solar, Nonconcentrator terrestrial photovoltaic reference cells, Photovoltaic power systems, Reference cells (for photovoltaic systems), Short circuit measurement, Solar collectors, Solar spectral irradiance, Spectral data-solar devices, Sunlight
1. Scope |
1.1 This test method is intended to be used for calibration and characterization of primary terrestrial, silicon photovoltaic reference cells to the global reference spectral irradiance distribution defined by Tables E892. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Primary global reference cells are calibrated outdoors in natural sunlight by reference to a pyranometer that is used to measure the global irradiance. 1.3 This test method applies only to the calibration of a photovoltaic cell which demonstrates a linear short-circuit current versus irradiance characteristic over its intended range of use, as defined in Test Method E1143. 1.4 This test method applies only to the calibration of single- or poly-crystalline silicon reference cells that have been fabricated with a single photovoltaic junction. 1.5 There is no similar or equivalent ISO standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |