Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
Automaticky přeložený název:
Standardní zkušební metoda pro zorné pole pro měření Tapping Machine dopadů přenosu hluku Floor - Stropní shromážděních a Associated podpůrných struktur
NORMA vydána dne 10.3.1997
Označení normy: ASTM E1007-97
Poznámka: NEPLATNÁ
Datum vydání normy: 10.3.1997
Kód zboží: NS-40118
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
field impact insulation class, impact sound insulation, impact sound pressure level, tapping machine, ICS Number Code 17.140.01 (Acoustic measurements and noise abatement in general), 91.120.20 (Acoustics in building. Sound insulation)
| 1. Scope | ||||||||||||||||||||||||||||
|
1.1 This test method covers the measurement of the transmission of impact sound generated by a standard tapping machine through floor-ceiling assemblies and associated supporting structures in field situations. 1.2 Measurements may be conducted on all types of floor-ceiling assemblies, including those with floating-floor or suspended ceiling elements, or both, and floor-ceiling assemblies surfaced with any type of floor-surfacing or floor-covering materials. 1.3 This test method further prescribes: 1.3.1 A uniform procedure for reporting test data, that is, the normalized one-third octave band sound pressure levels generated in the receiving room by the operation of the standard tapping machine on the floor-ceiling assembly. 1.3.2 The use of a single-figure classification rating, "Field Impact Insulation Class, FIIC" that can be used by architects, builders, and specification and code authorities for acoustical evaluation purposes in completed buildings. The FIIC is obtained by matching a standard reference contour to the plotted normalized one-third octave band sound pressure levels at each test frequency obtained in accordance with 8.2. For details regarding the derivation and significance of the FIIC, see Classification E989. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 02.05.2026 (Počet položek: 2 275 366)
© Copyright 2026 NORMSERVIS s.r.o.