Standard Guide for Radioscopy
Automaticky přeložený název:
Standardní Průvodce pro Radioscopy
NORMA vydána dne 1.6.2009
Označení normy: ASTM E1000-98(2009)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2009
Kód zboží: NS-40087
Počet stran: 20
Přibližná hmotnost: 60 g (0.13 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
configuration, electronic, module, non-destructive, radioscopy, real-time, Aluminum, Components analysis, Defects, Electrical conductors (semiconductors), Gamma radiation, Light transmission and reflection, Metals and metallic materials, Nonfilm detection, Performance--laboratory instrumentation/process, Radiation exposure, Radioscopic examination, Spectral data, Steel, Structural analysis/applications, X-irradiation, ICS Number Code 19.100 (Non-destructive testing)
Significance and Use | ||||||||||||||||||||||
Radioscopy is a versatile nondestructive means for examining an object. It provides immediate information regarding the nature, size, location, and distribution of imperfections, both internal and external. It also provides a rapid check of the dimensions, mechanical configuration, and the presence and positioning of components in a mechanism. It indicates in real-time the presence of structural or component imperfections anywhere in a mechanism or an assembly. Through manipulation, it may provide three-dimensional information regarding the nature, sizes, and relative positioning of items of interest within an object, and can be further employed to check the functioning of internal mechanisms. Radioscopy permits timely assessments of product integrity, and allows prompt disposition of the product based on acceptance standards. Although closely related to the radiographic method, it has much lower operating costs in terms of time, manpower, and material. Long-term records of the radioscopic image may be obtained through motion-picture recording (cinefluorography), video recording, or “still” photographs using conventional cameras. The radioscopic image may be electronically enhanced, digitized, or otherwise processed for improved visual image analysis or automatic, computer-aided analysis, or both. |
||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||
1.1 This guide is for tutorial purposes only and to outline the general principles of radioscopic imaging. 1.2 This guide describes practices and image quality measuring systems for real-time, and near real-time, nonfilm detection, display, and recording of radioscopic images. These images, used in materials examination, are generated by penetrating radiation passing through the subject material and producing an image on the detecting medium. Although the described radiation sources are specifically X-ray and gamma-ray, the general concepts can be used for other radiation sources such as neutrons. The image detection and display techniques are nonfilm, but the use of photographic film as a means for permanent recording of the image is not precluded. Note 1—For information purposes, refer to Terminology E 1316. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety precautionary statements, see Section 6. |
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|