Standard Specification for ASTM Liquid-in-Glass Thermometers
Automaticky přeložený název:
Standardní specifikace pro ASTM Liquid - in- Glass teploměry
NORMA vydána dne 1.11.2005
Označení normy: ASTM E1-05
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2005
Kód zboží: NS-40063
Počet stran: 64
Přibližná hmotnost: 192 g (0.42 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
bulb, liquid-in-glass thermometers, standard specification, stem, temperature, thermometer, ICS Number Code 17.200.20 (Temperature-measuring instruments)
| 1. Scope | ||||||||
|
1.1 This specification covers liquid-in-glass thermometers graduated in degrees Celsius or degrees Fahrenheit that are frequently identified and used in methods under the jurisdiction of the various technical committees within ASTM. The various thermometers specified are listed in . The inclusion of an IP number in indicates, where appearing, that the thermometer specification has been jointly agreed upon by the British Institute of Petroleum (IP) and ASTM. 1.2 This specification also covers adjustable-range enclosed-scale thermometers, graduated in degrees Celsius, which are used in ASTM methods. 1.3 The enclosed-scale thermometers are commonly called Beckmann thermometers. They are suitable for measuring small temperature differences not exceeding 6 C within a larger range of temperature. The thermometers are unsuitable for measuring Celsius- or kelvin-scale temperatures unless they have been compared with standard instruments immediately before use. 1.4 An alphabetic list of the ASTM Thermometers included in this standard is given in . 1.5 A list of ASTM Thermometers is given in to facilitate selection according to temperature range, immersion, and scale-error requirements. Note 1—For a listing of thermometers recommended for general laboratory use, the Scientific Apparatus Makers Association Specifications for General Purpose Glass Laboratory Thermometers may be consulted. Note 2—It has been found by experience that these ASTM Thermometers, although developed in general for specific tests, may also be found suitable for other applications, thus precluding the need for new thermometer specifications differing in only minor features. However, it is suggested that technical committees contact Subcommittee E20.05 before choosing a currently specified thermometer for a new method to be sure the thermometer will be suitable for the intended application. <1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
| 2. Referenced Documents | ||||||||
|
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.05.2026 (Počet položek: 2 275 493)
© Copyright 2026 NORMSERVIS s.r.o.