Standard Test Method for Water in Liquid Pine Chemicals
Automaticky přeložený název:
Standardní zkušební metoda pro vodu v kapalném Pine Chemicals
NORMA vydána dne 1.11.2012
Označení normy: ASTM D890-12
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2012
Kód zboží: NS-39630
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
azeotropic, coulometric, Karl Fischer, moisture, naval stores, pine chemicals, pine oil, tall oil, terpenes, turpentine, water, ICS Number Code 87.060.30 (Solvents)
Significance and Use | ||||
3.1 Many pine chemical products contain water as a result of the processes used for their production. Typically refined products such as terpenes, pine oil, tall oil fatty acids, and distilled tall oil contain only traces of water, but crude tall oil might contain 0.5 to 2.5 % of water. Although the Karl Fischer and coulometric methods are most applicable to low levels of moisture, these can be and are used at higher levels. The azeotropic distillation method is generally used at higher levels. |
||||
1. Scope | ||||
1.1 These test methods cover the quantitative determination of dissolved or occluded water present in any proportion in liquid pine chemicals, such as turpentine, pinene, dipentene, pine oil, tall oil, and tall oil fatty acids. Three methods of moisture testing are included. The Karl Fisher titration method is the preferred method for testing tall oil, Test Methods D803. 1.1.1 The Karl Fischer Titration method is based on the reaction between water and a complex reagent1.1.2 The coulometric titration method determines water content by electronic integration of a current sufficient to generate the precise amount of iodine from the required reagent to react with the water in the sample. 1.1.3 The azeotropic method utilizes the relatively low boiling point of water, as compared with other sample constituents, in a toluene or xylene matrix so that water is collected in a trap and measured. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||