Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Methods for Manganese in Water
Automaticky přeložený název:
Standardní zkušební metody pro Mangan ve vodě
NORMA vydána dne 1.8.2007
Označení normy: ASTM D858-07
Poznámka: NEPLATNÁ
Datum vydání normy: 1.8.2007
Kód zboží: NS-39495
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
atomic absorption, chelation, flame, graphite furnace, manganese, water, ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | ||||||||||||||||||||||||||||||||||
Elemental constituents in potable water, receiving water, and wastewater need to be identified for support of effective pollution control programs. Test Methods A, B, and C provide the techniques necessary to make such measurements. Although inhaled manganese dusts have been reported to be toxic to humans, manganese normally is ingested as a trace nutrient in both food and water. Because it is considered to be relatively nontoxic to man, as well as aquatic life, a limit of 50 μg/L has been established in the EPA National Secondary Drinking Water Regulations. This limit is based primarily on its ability to stain laundry and produce objectionable tastes in beverages. Manganese does not occur naturally as a metal but is found in various salts and minerals, frequently in association with iron compounds. Manganese is not mined in the United States except when manganese is contained in iron ores that are deliberately used to form ferro-manganese alloys. Manganese salts are used as fertilizer additives and are commonly found in surface and ground waters. |
||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||
1.1 These test methods cover the atomic absorption determination of dissolved and total recoverable manganese in water and certain wastewaters. Three test methods are given as follows:
1.2 Test Methods A, B, and C were used successfully on reagent grade and natural waters. Other matrices used in the study were brine (Test Method B), effluent from a wood treatment plant, and condensate from a medium BTU coal gasification process (Test Method C). It is the user's responsibility to ensure the validity of a test method for waters of untested matrices. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 11.7, 20.2, 20.9, and 22.10. 1.3 Former Test Method A (Colorimetric) was discontinued. For historical information, see Appendix X1. |
||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||
|
Poslední aktualizace: 17.09.2024 (Počet položek: 2 350 347)
© Copyright 2024 NORMSERVIS s.r.o.