Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in Soil by Multiple Reaction Monitoring Liquid Chromatography/Mass Spectrometry (LC/MS/MS)
Přeložit název
NORMA vydána dne 1.2.2020
Označení normy: ASTM D8018-15(2020)
Datum vydání normy: 1.2.2020
Kód zboží: NS-982902
Počet stran: 9
Přibližná hmotnost: 27 g (0.06 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
liquid chromatography, mass spectrometry, soil, (tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC),, ICS Number Code 13.080.10 (Chemical characteristics of soil)
Significance and Use | ||||||||||||||
5.1 This test method has been developed by the U.S. EPA Region 5 Chicago Regional Laboratory (CRL). 5.2 TTPC may be used in various industrial and commercial products for use as a biocide. Products containing TTPC have been approved for controlling algal, bacterial, and fungal slimes in industrial water systems.5.3 This method has been used to determine TTPC in sand, a commercial top soil, and four ASTM reference soils (Table 4). |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This procedure covers the determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in a soil matrix by extraction with acetone, filtration, dilution with water, and analysis by liquid chromatography/tandem mass spectrometry. TTPC is a biocide that strongly adsorbs to soils.1.2 The method detection limit (Note 1) (MDL) and reporting range (Note 2) for the target analyte are listed in Table 1. Note 1: The MDL is determined following the Code of Federal
Regulations, 40 CFR Part 136, Appendix B, as a guide utilizing
solvent extraction of soil. Two-gram sample of Ottawa sand was
utilized. A detailed process determining the MDL is explained in
the reference and is beyond the scope of this standard to be
explained here.
Note 2: Reporting range concentration is calculated from
Table 2 concentrations
assuming a 50-μL injection of the Level 1 calibration standard for
TTPC, and the highest level calibration standard with a 20-mL final
extract volume of a 2-g soil sample. Volume variations will change
the reporting limit and ranges.
1.2.1 The reporting limit in this test method is the minimum value below which data are documented as non-detects. Analyte detections between the method detection limit and the reporting limit are estimated concentrations and are not reported following this test method. The reporting limit is calculated from the concentration of the Level 1 calibration standard as shown in Table 2 for TTPC after taking into account a 2-g sample weight and a final extract volume of 20 mL in 75 % acetone/25 % water. The final extract volume is 20 mL because a 15-mL volume of acetone is added to each soil sample and only the liquid layer after extraction is filtered leaving the solid behind followed by the addition of 5 mL of water to the acetone extract. 1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Poslední aktualizace: 09.02.2025 (Počet položek: 2 224 354)