Standard Practice for Use of an Electrically Conductive Geotextile for Leak Location Surveys
Automaticky přeložený název:
Standardní praktiky pro použití elektricky vodivého geotextilie pro únik, Lokalita průzkumy
NORMA vydána dne 15.1.2013
Označení normy: ASTM D7852-13
Poznámka: NEPLATNÁ
Datum vydání normy: 15.1.2013
Kód zboží: NS-39189
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
conductive geotextile, geomembrane, leak detection, electrical leak location system, ICS Number Code 59.080.70 (Geotextiles)
Significance and Use | ||||||||
5.1 With the increased use of geomembranes as a barrier material to restrict liquid migration from one location to another, a need has been created for standardized tests by which the integrity of the installed geomembrane, including the seams, can be evaluated. This practice is intended to meet such a need whenever the sub-graded soil is non-conductive, or a geomembrane is installed on a non-conductive material. 5.2 The use of a suitably-conductive geotextile installed between a non-conductive soil or material and the geomembrane will permit electrical leak location survey to be conducted. 5.3 The compatibility of a conductive geotextile and leak location equipment shall be assessed for each leak location technique considered (covered or exposed, when applicable). A realistic small scale test shall have been conducted by the supplier of geotextile and / or leak detection equipment to demonstrate their mutual compatibility for a given leak detection technique. |
||||||||
1. Scope | ||||||||
1.1 This standard practice describes standard procedures for using a conductive geotextile with electrical methods to locate leaks in exposed geomembranes and geomembranes covered with water or earth materials containing moisture. 1.2 This standard practice provides guidance for the use of appropriate conductive geotextile used in leak location survey on geomembrane. This guide includes all types of conductive geotextile with sufficient conductivity for the particular electrical leak location method. A conductive geotextile is applicable to all types of geoelectric surveys when there is otherwise not a conductive layer under the geomembrane. 1.3 The leak stream itself being adequately conductive. A conductive geotextile is applicable to all types of geoelectric surveys when there is otherwise not a conductive layer under the geomembrane. 1.4 This standard practice is intended to ensure that leak location surveys can always be performed with a reasonable level of certainty. This standard practice provides guidance for the use of appropriate conductive geotextile used in leak location survey on geomembranes. 1.5 Leak location surveys can be used on non-conductive geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, other containment facilities and building applications such as in parking garages, decks and green roofs. The procedures are applicable for geomembranes made of non conductive materials such as polyethylene, polypropylene, polyvinyl chloride, chlorosulfonated polyethylene, bituminous material, and other electrically-insulating materials. Leak location survey involving conductive or partially conductive geomembranes are not within the scope of this document. 1.6 Warning—The electrical methods used for geomembrane leak location could use high voltages, resulting in the potential for electrical shock or electrocution. This hazard might be increased because operations might be conducted in or near water. In particular, a high voltage could exist between the water or earth material and earth ground, or any grounded conductor. These procedures are potentially VERY DANGEROUS, and can result in personal injury or death. Because of the high voltage that could be involved, and the shock or electrocution hazard, do not come in electrical contact with any leak unless the excitation power supply is turned off. The electrical methods used for geomembrane leak location should be attempted only by qualified and experienced personnel. Appropriate safety measures must be taken to protect the leak location operators as well as other people at the site. 1.7 This standard guide does not purport to address all of the safety and liability concerns, if any, associated with its use. It is the responsibility of the user of this standard guide to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historická
1.1.2012
Historická
1.7.2012
Historická
1.7.2012
Historická
1.1.2012
Historická
15.7.2012
Historická
1.7.2008
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 23.12.2024 (Počet položek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.