Standard Test Method for Individual Geogrid Junction Strength
Automaticky přeložený název:
Standardní zkušební metoda pro individuální Geomřížka Junction Pevnost
NORMA vydána dne 15.9.2011
Označení normy: ASTM D7737-11
Poznámka: NEPLATNÁ
Datum vydání normy: 15.9.2011
Kód zboží: NS-39040
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
geogrid, geogrid rib, geogrid junction, geosynthetic, geotextile, index test, tensile test ^DOI:
| Significance and Use | ||||||
|
This index test method is to be used to determine the strength of an individual junction in a geogrid product. The test is performed in isolation, while in service the junction is typically confined. Thus the results from this test method are not anticipated to be related to design performance. The value of junction strength can be used for manufacturing quality control, development of new products, or a general understanding of the in-isolation behavior of a particular geogrid’s junction (for example., in relation to handling during shipment and placement of the geogrid). This test method is applicable to geogrid products with essentially orthogonal ribs, yarns or straps, that is, geogrids which are composed of ribs, yarns or straps that are entangled through weaving or knitting, welded, bonded or formed through drawing. |
||||||
| 1. Scope | ||||||
|
1.1 This test method is an index test which provides a procedure for determining the strength of an individual geogrid junction, also called a node. The test is configured such that a single rib is pulled from its junction with a cross-rib to obtain the maximum force, or strength of the junction. The procedure allows for the use of two different clamps with the appropriate clamp selected to minimize the influence of the clamping mechanism on the specific type of geogrid to be tested. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||