Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Solvent-Free Membrane Recoverable Oil and Grease by Infrared Determination
Automaticky přeložený název:
Standardní zkušební metoda pro neobsahuje rozpouštědla membránového obnovitelného oleje a maziva infračervenými Stanovení
NORMA vydána dne 1.11.2011
Označení normy: ASTM D7575-11
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2011
Kód zboží: NS-38754
Počet stran: 12
Přibližná hmotnost: 36 g (0.08 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
dispersive infrared, filtometric infrared, FTIR, grease, infrared transmission, oil, solid phase extraction, spectroscopy, water: FTIR analysis, Industrial wastewater applications, Infrared (IR) analysis--water, Recoverable elements (from water), Spectroscop, ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | ||||||||||||
The presence and concentration of oil and grease in domestic and industrial wastewater is of concern to the public because of its deleterious health, environmental, safety, and aesthetic effects. Regulations and standards have been established that require monitoring of oil and grease in water and wastewater. Note 1—Different oil and grease materials may have different infrared absorptivities. Certain materials, such as synthetic silicone-based or perfluorinated oils, may have absoptivities inconsistent with those of naturally occurring oil and grease materials. Caution should be taken when testing matrices suspected of containing proportions of these materials. In such cases, laboratory spike samples, laboratory check samples, equivalency testing, or combinations thereof, using these materials in question may be appropriate. |
||||||||||||
1. Scope | ||||||||||||
1.1 This test method covers the determination of oil and grease in produced and waste water samples over the concentration range outlined in Table 1 that can be extracted with an infrared-amenable membrane and measured by infrared transmission through the membrane. 1.2 This method defines oil and grease in water as that which is extractable in the test method and measured by infrared transmission. 1.3 The method detection limit (MDL) and recommended reporting range are listed in Table 1. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 MDL and Reporting Range
A MDL and recommended reporting range determined by Section 12.4, which follows the Code of Federal Regulations, 40 CFR Part 136, Appendix B; limits should be determined by each operator. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Historická
1.8.2010
Historická
15.6.2013
Historická
1.10.2009
Historická
1.10.2009
Historická
15.9.2008
Historická
15.6.2012
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 23.12.2024 (Počet položek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.