Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Sampling of Liquids in Waste Management Activities Using a Peristaltic Pump
Automaticky přeložený název:
Standardní praxe pro odběr vzorků kapalin v nakládání s odpady, pomocí peristaltické pumpy
NORMA vydána dne 1.2.2013
Označení normy: ASTM D7353-07(2013)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.2.2013
Kód zboží: NS-38260
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
peristaltic, pump, sampling, waste streams, ICS Number Code 23.080 (Pumps)
Significance and Use | ||||||||||||||||||||||||
5.1 This practice can be used in sampling drums, tanks, and similar containers and in sampling monitoring and waste wells including small diameter (1 in.) wells. The pump can collect samples from multiple depths. The samples can be high-viscosity fluids, aggressive and corrosive fluids, high-purity solutions and abrasive fluids. The pump can be used to mix samples (see D6063). 5.2 Peristaltic pumps use a vacuum to transport the samples. This vacuum may cause some degassing and loss of volatile organic compounds (VOCs) from the sample. When precise quantitative data for VOCs and dissolved gases are not required, peristaltic pumps may be used. 5.3 The pump is self-priming, runs dry without damage, and is completely isolated from the pumped fluid. A sample can be taken on the intake or discharge side of the pump. 5.4 Some additional advantages of the peristaltic pump are: decontamination of the pump motor is not necessary and the tubing in the pump is disposable and easy to replace. The pumps can be easily started and stopped and can pump fluids at a wide range of pressures and flow rates. 5.5 The place, quality and quantity, frequency, and time of sampling is dependent upon the decisions that are to be made (see D6250), sampling design (see D6311), the sample, the heterogeneity of the samples (see D5956), how representative the sample is (see D6044), and the parameters to be tested as determined by the data quality objectives (DQOs) (see D5792). |
||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||
1.1 This practice covers the use of a peristaltic pump for sampling liquids from multiple depths. It is applicable for a wide range of fluids including: high-viscosity fluids, aggressive and corrosive fluids, high-purity solutions and abrasive fluids. It is especially useful for sampling liquids that require complete isolation from the pump. 1.2 This practice includes the determination of sample depth, pump set up and collecting a sample to be analyzed. 1.3 This practice is not intended to give detailed instructions for running a peristaltic pump or recommend which peristaltic pump to purchase. It instructs the field personnel how to connect the pump and collect a sample. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||
|
Historická
1.11.2009
Historická
15.11.2011
Historická
1.4.2014
Historická
1.5.2012
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 23.12.2024 (Počet položek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.