Standard Test Method for Screening Trichloroethylene (TCE)-Contaminated Media Using a Heated Diode Sensor (Includes all amendments And changes 8/17/2011).
Automaticky přeložený název:
Standardní zkušební metoda pro screening Trichlóretylén ( TCE ) -Contaminated médií pomocí diodového senzor Vyhřívání
NORMA vydána dne 1.10.2006
Označení normy: ASTM D7203-06e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2006
Kód zboží: NS-37854
Počet stran: 14
Přibližná hmotnost: 42 g (0.09 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
field screening, halogenated volatile organic compounds (HVOCs), heated diode sensor, soils, trichloroethylene (TCE), water, ICS Number Code 13.080.10 (Chemical characteristics of soil)
| 1. Scope | ||||
|
1.1 This test method describes procedures for screening media known to contain the halogenated volatile organic compound (HVOC), trichloroethylene (TCE). Procedure A is to be used for screening soil known to contain TCE and Procedure B is to be used for screening water known to contain TCE. 1.1.1 Both Procedures A and B involve measuring the TCE concentration in the headspace above a sample using a heated diode sensor device. From this measurement, an estimated concentration of TCE in the sample can be determined. Any TCE remaining in the sample is not measured. Any other HVOC present in the sample will be reported as TCE. 1.2 Procedure A can also be used for screening the headspace above a soil suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the soil. Procedure B can also be used for screening the headspace above a water suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the water. For both procedures, any HVOC contamination remaining in the soil or water is not detected by this test method. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the application of regulatory limitations prior to use. Note 1The diode sensor is heated to temperatures ranging between approximately 600 and 1000 C (see ) and as a result could be a source of ignition. |
||||
| 2. Referenced Documents | ||||
|