Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determination of Trace Elements in Middle Distillate Fuels by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení stopových prvků ve střední destilát paliv s indukčně vázanou plazmou atomovou emisní spektrometrií ( ICP - AES )
NORMA vydána dne 1.4.2005
Označení normy: ASTM D7111-05
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2005
Kód zboží: NS-37583
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
aviation turbine fuel, diesel fuel, elemental analysis, fuel, ICP, inductively coupled plasma atomic emission spectrometry, internal standard, middle distillate fuels, trace elements, ICS Number Code 75.160.20 (Liquid fuels)
| 1. Scope | ||||||||||||||||||
|
1.1 This test method covers the determination of selected elements in middle distillate fuels by inductively coupled plasma atomic emission spectrometry (ICP-AES). The specific elements are listed in . The concentration range of this test method is approximately 0.1 to 2.0 mg/kg. The test method may be used for concentrations outside of this range; however, the precision statements may not be applicable. Middle distillate fuels covered in this test method have all distillation fractions contained within the boiling range of 150 to 390C. This includes, but is not limited to, diesel fuels and aviation turbine fuels. 1.2 This test method is not intended to analyze insoluble particulates. However, very small particulate matter (smaller than a micrometre) will be carried into the plasma and be included in the quantitative analysis. 1.3 This test method may give a result that is higher than the true value if an analyte is present in the sample in a form which is sufficiently volatile. For example, hexamethyldisiloxane will generate a biased high result for silicon. 1.4 The values stated in SI units are to be regarded as standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||
|
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 15.07.2026 (Počet položek: 2 287 995)