Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Testing Vertical Strip Drains in the Crimped Condition (Includes all amendments And changes 8/3/2022).
Automaticky přeložený název:
Standardní zkušební metoda pro zkoušení vertikální Gazy kanalizace ve přilemovaném stavu
NORMA vydána dne 1.1.2014
Označení normy: ASTM D6918-09(2014)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2014
Kód zboží: NS-37001
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
constant head, crimped, flow velocity, percent change, uncrimped, vertical strip drain confined crimp test, ICS Number Code 91.060.20 (Roofs)
Significance and Use | ||||
5.1 This test method is considered satisfactory for the acceptance of commercial shipments of vertical strip drains. 5.1.1 In case of dispute arising from differences in reported test results when using this test method for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative tests to determine if there is any statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. As a minimum, the two parties should take a group of test specimens that as homogenous as possible, and that are from a lot of material of the type in question. The test specimens should be randomly assigned in numbers to each laboratory for testing. The average results from the two laboratories should be compared using Student's t-test for unpaired data and an acceptable probability level chosen by the two parties before the start of testing. If a bias is found, either its cause must be found and corrected, or the purchaser and the supplier must agree to interpret future test results in light of the known bias. 5.2 Vertical strip drains are installed in areas where it is desired to increase the rate of soil consolidation. It has been shown that as the soil around the vertical strip drain consolidates, a crimp may form in the vertical strip drain due to the movement of the drain in the area of soil consolidation. 5.3 This test method can be used to evaluate if there is any reduction in flow rate of water through the drain due to the crimping, and what effect, if any, this crimping may have on the rate of consolidation of the soil. |
||||
1. Scope | ||||
1.1 This test method is a performance test that measures the effect crimping has on the ability of vertical strip drains to transmit water parallel to the plane of the drain. 1.2 This test method is applicable to all vertical strip drains. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Historická
15.2.2011
Historická
15.2.2011
Historická
1.4.2011
Historická
1.5.2014
Historická
1.12.2011
Historická
1.6.2014
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 07.05.2024 (Počet položek: 2 897 585)
© Copyright 2024 NORMSERVIS s.r.o.