Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Evaluation of Automotive Engine Oils in the Sequence VIII Spark-Ignition Engine (CLR Oil Test Engine)
Automaticky přeložený název:
Standardní zkušební metoda pro vyhodnocení Automotive motorové oleje v pořadí VIII zážehového motoru ( CLR Oil test Engine )
NORMA vydána dne 10.5.2003
Označení normy: ASTM D6709-03
Poznámka: NEPLATNÁ
Datum vydání normy: 10.5.2003
Kód zboží: NS-36221
Počet stran: 55
Přibližná hmotnost: 165 g (0.36 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
bearing weight loss, CLR oil test engine, copper-lead bearings, engine oil, oil consumption, Sequence VIII test, shear stability
| 1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||
|
1.1 This test method covers the evaluation of automotive engine oils (SAE grades 5W, 10W, 20, 30, 40, and 50, and multiviscosity grades) intended for use in spark-ignition gasoline engines. The test procedure is conducted using a carbureted, spark-ignition Cooperative Lubrication Research (CLR) Oil Test Engine (also referred to as the Sequence VIII test engine in this test method) run on unleaded fuel. An oil is evaluated for its ability to protect the engine and the oil from deterioration under high-temperature and severe service conditions. The test method can also be used to evaluate the viscosity stability of multiviscosity-graded oils. Companion test methods used to evaluate engine oil performance for specification requirements are discussed in the latest revision of Specification D 4485. 1.2 Correlation of test results with those obtained in automotive service has not been established. Furthermore, the results obtained in this test are not necessarily indicative of results that will be obtained in a full-scale automotive spark-ignition or compression-ignition engine, or in an engine operated under conditions different from those of the test. The test can be used to compare one oil with another. 1.3 The values stated in SI units are to be regarded as standard, except for (1) volume which is given in the metric, but non-SI, litre, (2) certain tube measurements which are given in inch-pound units, (3) cylinder bore and stroke in both SI and inch-pound units (the inch-pound being the standard) and (4) piston displacement given in metric (non-SI) and inch-pound units (the inch-pound being the standard). In respect to (3) and (4) the inch-pound units are shown first and the SI units in parentheses. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are provided throughout this test method. |
||||||||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||
|
Poslední aktualizace: 30.07.2026 (Počet položek: 2 290 198)
© Copyright 2026 NORMSERVIS s.r.o.