Standard Test Method for Rust-Preventing Characteristics of Inhibited Mineral Oil in the Presence of Water (Includes all amendments And changes 1/3/2020).
Automaticky přeložený název:
Standardní zkušební metoda pro Rust-Prevence Charakteristika inhibitovaná minerálního oleje v přítomnosti vody
NORMA vydána dne 1.10.2014
Označení normy: ASTM D665-14e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2014
Kód zboží: NS-580648
Počet stran: 10
Přibližná hmotnost: 30 g (0.07 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
circulating oils, heavier-than-water fluids, hydraulic oils, inhibited mineral oil, rust-preventing characteristics, steam-turbine oils,, ICS Number Code 75.080 (Petroleum products in general)
Significance and Use | ||||||||||||||||
5.1 In many instances, such as in the gears of a steam turbine, water can become mixed with the lubricant, and rusting of ferrous parts can occur. This test indicates how well inhibited mineral oils aid in preventing this type of rusting. This test method is also used for testing hydraulic and circulating oils, including heavier-than-water fluids. It is used for specification of new oils and monitoring of in-service oils. Note 3: This test method was used as a basis for Test Method
D3603. Test Method
D3603 is used to test the oil
on separate horizontal and vertical test rod surfaces, and can
provide a more discriminating evaluation.
|
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the evaluation of the ability of inhibited mineral oils, particularly steam-turbine oils, to aid in preventing the rusting of ferrous parts should water become mixed with the oil. This test method is also used for testing other oils, such as hydraulic oils and circulating oils. Provision is made in the procedure for testing heavier-than-water fluids. Note 1: For synthetic fluids, such as phosphate ester types,
the plastic holder and beaker cover should be made of chemically
resistant material suitable for the type of fluid
tested.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.4 – 7.6. |
||||||||||||||||