Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Performance Testing of Process Analyzers for Aromatic Hydrocarbon Materials
Automaticky přeložený název:
Standardní praktiky pro testování výkonnosti procesu analyzátory pro aromatický uhlovodík materiály
NORMA vydána dne 10.12.2000
Označení normy: ASTM D6621-00
Poznámka: NEPLATNÁ
Datum vydání normy: 10.12.2000
Kód zboží: NS-35926
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
analyzer, on-line, performance testing, process stream analyzer, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
| 1. Scope | ||||||||||
|
1.1 This practice serves as a practical guide for the performance testing of process stream analyzers specifically for measuring chemical or physical characteristics of liquid aromatic hydrocarbon materials for production or certification of these materials. The practice may be applicable to other hydrocarbon stream analyzers as well. 1.2 Only external methods (complete substitution of the process stream with a standard) of control sample introduction are included. Internal methods are beyond the scope of this practice. 1.3 Methods for resetting key operational parameters of analyzers to match predefined limits are provided by vendors and are not included in this practice. 1.4 Analyzer validation procedures are covered in Practices D3764 and D6122, not in this practice. 1.5 Procedures for statistically interpreting data from automatic sampling process stream analyzers are outlined. 1.6 The implementation of this practice requires that the analyzer be installed according to APIRP-550 (1), and be in agreement with the analyzer supplier's recommendations. Also, it assumes that the analyzer is designed to monitor the specific material parameter of interest, and that at the time of initial or periodic validation, the analyzer was operating at the conditions specified by the manufacturer and consistently with the primary test method. 1.7 The units of measure used in this practice shall be the same as those applicable to the test primary method used for analyzer validation. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use. |
||||||||||
| 2. Referenced Documents | ||||||||||
|