Standard Test Method for Determination of Dissolved Inorganic Anions in Aqueous Matrices Using Capillary Ion Electrophoresis and Chromate Electrolyte
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení rozpuštěných anorganických aniontů ve vodných matric kapilární elektroforézy Ion a Chromate elektrolyt
NORMA vydána dne 1.9.2010
Označení normy: ASTM D6508-10
Poznámka: NEPLATNÁ
Datum vydání normy: 1.9.2010
Kód zboží: NS-35424
Počet stran: 17
Přibližná hmotnost: 51 g (0.11 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
anion, capillary electrophoresis, drinking water, ion analysis, reagent water, substitute wastewater, wastewater, Substitute wastewater, Sulfate (ion) analysis, Wastewater testing/treatment, Anions content, Bromide (ion) analysis, Capillary ion electrophoresis (CIE), Chloride analysis, Drinking water, Fluoride (ion) analysis, Inorganic anions, Inorganic chemical analysis--water, Nitrate (ion) analysis, Orthophosphate content, Phosphate (ion) analysis, Reagent water
Significance and Use | ||||||||||||||||||||
Capillary ion electrophoresis provides a simultaneous separation and determination of several inorganic anions using nanolitres of sample in a single injection. All anions present in the sample matrix will be visualized yielding an anionic profile of the sample. Analysis time is less than 5 minutes with sufficient sensitivity for drinking water and wastewater applications. Time between samplings is less than seven minutes allowing for high sample throughput. Minimal sample preparation is necessary for drinking water and wastewater matrices. Typically, only a dilution with water is needed. This test method is intended as an alternative to other multi-analyte methods and various wet chemistries for the determination of inorganic anions in water and wastewater. Compared to other multi-analyte methods the major benefits of CIE are speed of analysis, simplicity, and reduced reagent consumption and operating costs. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method covers the determination of the inorganic anions fluoride, bromide, chloride, nitrite, nitrate, ortho-phosphate, and sulfate in drinking water, wastewater, and other aqueous matrices using capillary ion electrophoresis (CIE) with indirect UV detection. See Figs. 1-6. 1.2 The test method uses a chromate-based electrolyte and indirect UV detection at 254 nm. It is applicable for the determination or inorganic anions in the range of 0.1 to 50 mg/L except for fluoride whose range is 0.1 to 25 mg/L. 1.3 It is the responsibility of the user to ensure the validity of this test method for other anion concentrations and untested aqueous matrices. Note 1—The highest accepted anion concentration submitted for precision and bias extend the anion concentration range for the following anions: Chloride to 93 mg/L, Sulfate to 90 mg/L, Nitrate to 72 mg/L, and ortho-phosphate to 58 mg/L. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 23.12.2024 (Počet položek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.