Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Methods for Composition of Turpentine and Related Terpene Products by Capillary Gas Chromatography (Includes all amendments And changes 1/12/2015).
Automaticky přeložený název:
Standardní zkušební metody pro složení terpentýnu a souvisejících terpenový produkty pomocí kapilární plynové chromatografie
NORMA vydána dne 1.6.2010
Označení normy: ASTM D6387-99(2010)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2010
Kód zboží: NS-34933
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
capillary column, dipentene, gas chromatography, pine oil, turpentine, Pine oil, Terpene products, Turpentine, Capillary gas chromatography, Composition analysis--paints/related coatings/materials, Dipentene, Gas chromatography (GC)--paints/related coatings/materials
| Significance and Use | ||||||||||||
|
Earlier methods for characterizing turpentine and related terpene products were based on physical properties, such as those in Specification D13 and Test Methods D801 and D802, and packed column gas chromatography for the major constituents (for example, α-pinene, β-pinene) as in Test Method . As terpene products became widely used as chemical raw material, the separation and quantitation of compounds present at lower concentrations in the product became more important. The capillary gas chromatographic technique described in these test methods is a rapid and convenient means to perform these analyses. |
||||||||||||
| 1. Scope | ||||||||||||
|
1.1 These test methods describe the determination of the amounts of α-pinene, β-pinene, dipentene, terpene alcohols, and other terpene compounds in turpentine and related terpene products using capillary gas chromatography. The two methods for determining the amount of the individual terpene compounds are the “internal standard” method, which yields absolute values, and the “area percent” method, which yields relative values. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of the standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 1—Overall this test method gives excellent repeatability but only moderate reproducibility. This greater than normal differential is a consequence of the variety of gas chromatography (GC) columns and other variables used by participants. These variables, coupled with the complex composition of the test products, enabled some workers to separate peaks that others reported as one peak; thus, this test method gives excellent precision within a given laboratory on a given GC. When laboratory to laboratory comparison have to be made, however, it is essential that the GC operating conditions be defined closely. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 11.08.2026 (Počet položek: 2 292 404)
© Copyright 2026 NORMSERVIS s.r.o.