Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determination of Vapor Pressure of Crude Oil: VPCRx (Expansion Method)
Přeložit název
NORMA vydána dne 1.6.2020
Označení normy: ASTM D6377-20
Datum vydání normy: 1.6.2020
Kód zboží: NS-997615
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
crude oil, expansion method, Reid vapor pressure, vapor pressure,, ICS Number Code 75.040 (Crude petroleum)
Significance and Use | ||||||||||||||||
5.1 Vapor pressure of crude oil at various V/Ls is an important physical property for shipping and storage. Note 2: A vapor-liquid ratio of 0.02:1 (X = 0.02) mimics
closely the situation of an oil tanker.
5.2 Vapor pressure of crude oil is important to crude oil producers and refiners for general handling and initial refinery treatment. 5.3 The vapor pressure determined by this test method at a vapor-liquid ratio of 4:1 (VPCR4) of crude oil at 37.8 °C can be related to the vapor pressure value determined on the same material when tested by Test Method D323 (see Appendix X1). 5.4 Air saturation of crude oil shall not be done to avoid potential vapor loss. However air saturation of the chilled verification fluid is mandatory (see 7.2 and Section 11). 5.5 This test method can also be applied in online applications. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the use of automated vapor pressure instruments to determine the vapor pressure exerted in vacuum of crude oils. This test method is suitable for testing samples that exert a vapor pressure between 25 kPa and 180 kPa at 37.8 °C at vapor-liquid ratios from 4:1 and 0.02:1 (X = 4 and 0.02). Note 1: This test method is suitable for the determination of
the vapor pressure of crude oils at temperatures from 0 °C to
100 °C and pressures up to 500 kPa, but the precision and bias
statements (see Section 14)
may not be applicable. The current precision of the method is
limited at vapor-liquid ratios of 0.02 and 4. (Section 14 is inclusive of vapor-liquid ratios of
0.02 and 4).
1.2 This test method also allows the determination of vapor pressure for crude oil samples having pour points above 15 °C provided the proper sample handling, transfer, and analysis procedures are followed. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.