Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Separation of Contaminants in Polymers Using an Extruder Filter Test
Automaticky přeložený název:
Standardní praxe pro separaci kontaminantů v polymerech Použití Extruder filtru test
NORMA vydána dne 10.7.2003
Označení normy: ASTM D6265-98(2003)
Poznámka: NEPLATNÁ
Datum vydání normy: 10.7.2003
Kód zboží: NS-34448
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
contamination, extruder filtration test, polyolefins, recycled plastics, ICS Number Code 83.020 (Manufacturing processes in the rubber and plastics industries)
| Significance and Use | ||||||||
|
Presence of paper, metal, gels, incompatible polymer, or other extraneous contamination in polymers, including recycled polymers, may cause problems with extrusion and subsequent processing of the material. This procedure is useful for separating gross contaminants from polymers. For example, the procedure is useful for determining the quality of resins to be used in fiber applications. If desired, the isolated contaminants may be subsequently identified by the appropriate visual or instrumental procedures. |
||||||||
| 1. Scope | ||||||||
|
1.1 This practice covers a means to separate the unmolten particles, gels, and impurities contaminating a polymer sample. The procedure may be used to remove gels and incompatible materials that may cause imperfections in the final extruded product. Under pressure, most gels will break up or deform and pass through a wire mesh filter, however high molecular weight gels may not break up or deform. 1.2 If desired, materials isolated on a wire mesh filter can subsequently be identified by spectroscopic or other analytical means. Note 1—Although not presented as a quantitative method, the procedure presented in this practice may be used to provide quantitative results at the discretion of the user. The user assumes the responsibility to verify the reproducibility of quantitative results. Detection limit depends on the mesh size of the filter screen, but the procedure is generally applicable to the separation of immiscible contaminants present at concentrations greater than 0.1 %. 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see Section 8. Note 2—There is no equivalent ISO standard. |
||||||||
| 2. Referenced Documents | ||||||||
|
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 13.08.2026 (Počet položek: 2 293 179)
© Copyright 2026 NORMSERVIS s.r.o.