Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method (Analytical Procedure) for Determining Hydraulic Properties of a Confined Aquifer Taking into Consideration Storage of Water in Leaky Confining Beds by Modified Hantush Method
Přeložit název
NORMA vydána dne 1.1.2017
Označení normy: ASTM D6028-17
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2017
Kód zboží: NS-674992
Počet stran: 9
Přibližná hmotnost: 27 g (0.06 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
aquifers, aquifer tests, confined aquifers, confining beds, control wells, groundwater, hydraulic properties, leakance, leaky aquifers, observation wells, storage coefficient, transmissivity ,, ICS Number Code 13.060.10 (Water of natural resources)
Significance and Use | ||||||||
5.1 Assumptions: 5.1.1 The control well discharges at a constant rate, 5.1.2 The control well is of infinitesimal diameter and fully penetrates the aquifer. 5.1.3 The aquifer is homogeneous, isotropic, and areally extensive. 5.1.4 The aquifer remains saturated (that is, water level does not decline below the top of the aquifer). 5.1.5 The aquifer is overlain or underlain, or both, everywhere by confining beds individually having uniform hydraulic conductivities, specific storages, and thicknesses. The confining beds are bounded on the distal sides by one of the cases shown in Fig. 1. 5.1.6 Flow in the aquifer is two-dimensional and radial in the horizontal plane. 5.2 The geometry of the well and aquifer system is shown in Fig. 1. 5.3 Implications of Assumptions: 5.3.1 Paragraph 5.1.1 indicates that the discharge from the control well is at a constant rate. Paragraph 8.1 of Test Method D4050 discusses the variation from a strictly constant rate that is acceptable. A continuous trend in the change of the discharge rate could result in misinterpretation of the water-level change data unless taken into consideration. Note 1: The quality of the result produced by this standard is
dependent on the competence of the personnel performing it, and the
suitability of the equipment and facilities used. Agencies that
meet the criteria of Practice D3740 are generally considered capable of
competent and objective testing/sampling/inspection/etc. Users of
this standard are cautioned that compliance with Practice
D3740 does not in itself
assure reliable results. Reliable results depend on many factors;
Practice D3740 provides a
means of evaluating some of those factors.
5.3.2 The leaky confining bed problem considered by the modified Hantush method requires that the control well has an infinitesimal diameter and has no storage. Moench 5.3.3 The modified Hantush method assumes, for Cases 1 and 3 (see Fig. 1), that the heads in source layers on the distal side of confining beds remain constant. Neuman and Witherspoon (7) developed a solution for a case that could correspond to Hantush's Case 1 with K" = O = S" except that they do not require the head in the unpumped aquifer to remain constant. For that case, they concluded that the drawdowns in the pumped aquifer would not be affected by the properties of the other, unpumped, aquifer when (Neuman and Witherspoon 5.3.4 Implicit in the assumptions are the conditions that the flow in the confining beds is essentially vertical and in the aquifer is essentially horizontal. Hantush's That form of relation between aquifer and confining bed properties may also be a useful guide for the case of two leaky confining beds. |
||||||||
1. Scope | ||||||||
1.1 This test method covers an analytical procedure for determining the transmissivity and storage coefficient of a confined aquifer taking into consideration the change in storage of water in overlying or underlying confining beds, or both. This test method is used to analyze water-level or head data collected from one or more observation wells or piezometers during the pumping of water from a control well at a constant rate. With appropriate changes in sign, this test method also can be used to analyze the effects of injecting water into a control well at a constant rate. 1.2 This analytical procedure is used in conjunction with Test Method D4050. 1.3 Limitations—The valid use of the modified Hantush method 1.4 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. 1.4.1 The procedures used to specify how data are collected/recorded and calculated in the standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of these test methods to consider significant digits used in analysis methods for engineering data. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.