Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for (Analytical Procedure) Determining Hydraulic Conductivity of an Unconfined Aquifer by Overdamped Well Response to Instantaneous Change in Head (Slug) (Withdrawn 2013)
Automaticky přeložený název:
Standardní zkušební metoda pro ( Analytical Procedure ) Stanovení hydraulická vodivost k unconfined Aquifer podle přetlumenému stochastickému Well reakci na okamžité změny ve Head ( Slug ) (Withdrawn 2013 )
NORMA vydána dne 1.11.2004
Označení normy: ASTM D5912-96(2004)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2004
Kód zboží: NS-33059
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
aquifers, aquifer tests, control wells, groundwater, hydraulic conductivity, slug test: Aquifers, Environmental site assessment (ESA)--soil/rock, Transmissivity, Unconfined/unconsolidated aquifers, Water level observation, Ground water, Hydraulic conductivity/transmissivity, Overdamped well-aquifer system, Slug tests, Storage--aquifers, ICS Number Code 07.060 (Geology. Meteorology. Hydrology), 93.020 (Earth works. Excavations. Foundation construction. Underground works)
| Significance and Use | ||||||||||||
|
Assumptions of Solution: Drawdown (or mounding) of the water table around the well is negligible. Flow above the water table can be ignored. Head losses as the water enters or leaves the well are negligible. The aquifer is homogeneous and isotropic. Implications of Assumptions: The mathematical equations applied ignore inertial effects and assume that the water level returns to the static level in an approximate exponential manner. The geometric configuration of the well and aquifer are shown in Fig. 1, that is after Fig. 1 of Bouwer and Rice. For filter-packed wells, Eq 1 applies to
cases in which the filter pack remains saturated. If some of the
filter pack is dewatered during testing, rc 2 should be replaced by
the following:
Note 6—Short term refers to the duration of the slug test. Note—See Fig. 1 of Footnote 2. FIG. 1 Geometry and Symbols of a Partially Penetrating, Partially Perforated Well in Unconfined Aquifer with Gravel Pack or Developed Zone Around Perforated Section |
||||||||||||
| 1. Scope | ||||||||||||
|
1.1 This test method covers the determination of hydraulic conductivity from the measurement of inertial force free (overdamped) response of a well-aquifer system to a sudden change in water level in a well. Inertial force free response of the water level in a well to a sudden change in water level is characterized by recovery to initial water level in an approximate exponential manner with negligible inertial effects. 1.2 The analytical procedure in this test method is used in conjunction with the field procedure in Test Method D4044 for collection of test data. 1.3 Limitations—Slug tests are considered to provide an estimate of hydraulic conductivity. The determination of storage coefficient is not possible with this test method. Because the volume of aquifer material tested is small, the values obtained are representative of materials very near the open portion of the control well. Note 1—Slug tests are usually considered to provide estimates of the lower limit of the actual hydraulic conductivity of an aquifer because the test results are so heavily influenced by well efficiency and borehole skin effects near the open portion of the well. The portion of the aquifer that is tested by the slug test is limited to an area near the open portion of the well where the aquifer materials may have been altered during well installation, and therefore may significantly effect the test results. In some cases the data may be misinterpreted and result in a higher estimate of hydraulic conductivity. This is due to the reliance on early time data that is reflective of the hydraulic conductivity of the filter pack surrounding the well. This effect was discussed by Bouwer. In addition, because of the reliance on early time data, in aquifers with medium to high hydraulic conductivity, the early time portion of the curve that is useful for this data analyses is too short (for example, <10 s) for accurate measurement; therefore, the test results begin to greatly underestimate the true hydraulic conductivity. 1.4 The values stated in SI units are to be regarded as the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
||||||||||||
Poslední aktualizace: 26.08.2026 (Počet položek: 2 298 418)
© Copyright 2026 NORMSERVIS s.r.o.