Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Rubber-Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Iodine Value
Automaticky přeložený název:
Standardní zkušební metoda pro gumový zjišťování zbytkové nenasycené vazby hydrogenované nitrilové pryže (HNBR) jódem Hodnota
NORMA vydána dne 1.6.2010
Označení normy: ASTM D5902-05(2010)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.6.2010
Kód zboží: NS-33021
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
HNBR, iodine value, residual unsaturation, HNBR (hydrogenated nitrile rubber), Iodine value, Nitrile rubber, Residual unsaturation, Unsaturation, WIJS procedure (iodine value), ICS Number Code 71.040.40 (Chemical analysis), 83.060 (Rubber)
Significance and Use | ||||||
Hydrogenated nitrile rubbers are available at different levels of unsaturation and different acrylonitrile content. Highly saturated grades offer optimum resistance to aging, such as exposure to heat, ozone and chemicals, and can be cured effectively only with peroxides or high energy radiation. Partially unsaturated grades can be cured by sulfur systems in addition to peroxides and high energy radiation. This test method provides a technique to determine the unsaturation level of hydrogenated nitrile rubbers in the raw, unvulcanized state. It can be used for research and development, quality control, and referee purposes. |
||||||
1. Scope | ||||||
1.1 This test method covers the Wiijs procedure for the determination of unsaturation (iodine value) in hydrogenated nitrile rubbers. 1.2 This test method is applicable only to those hydrogenated nitrile rubbers derived from copolymers of acrylonitrile and butadiene. 1.3 Iodine values are reported in centigrams of iodine per gram of HNBR [cg(I2)/g]. Higher iodine values indicate higher levels of unsaturation. 1.4 This test method is appropriate for calculating the percent residual unsaturation of hydrogenated nitrile rubber if the iodine value of the base polymer before hydrogenation has been determined. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.