Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for (Analytical Procedure) Determining Transmissivity of Confined Nonleaky Aquifers by Critically Damped Well Response to Instantaneous Change in Head (Slug)
Automaticky přeložený název:
Standardní zkušební metoda pro ( analytický postup ) stanovení propustnosti stísněném Nonleaky aquiferů kriticky tlumený Well reakci na okamžité změny ve Head ( Slug )
NORMA vydána dne 1.1.2000
Označení normy: ASTM D5881-95(2000)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2000
Kód zboží: NS-32929
Počet stran: 9
Přibližná hmotnost: 27 g (0.06 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
aquifers, aquifer tests, ground water, hydraulic conductivity, observation wells, slug test, storage, coefficient, transmissivity, ICS Number Code 07.060 (Geology. Meteorology. Hydrology)
| 1. Scope | ||||||||||||
|
1.1 This test method covers determination of transmissivity from the measurement of water-level response to a sudden change of water level in a well-aquifer system characterized as being critically damped or in the transition range from underdamped to overdamped. Underdamped response is characterized by oscillatory changes in water level; overdamped response is characterized by return of the water level to the initial static level in an approximately exponential manner. Overdamped response is covered in Guide D4043; underdamped response is covered in D5785. 1.2 The analytical procedure in this test method is used in conjunction with Guide D4043 and the field procedure in Test Method D4044 for collection of test data. 1.3 The values stated in SI units are to be regarded as standard. 1.4 Limitations--Slug tests are considered to provide an estimate of the transmissivity of an aquifer near the well screen. The method is applicable for systems in which the damping parameter, [zeta], is within the range from 0.2 through 5.0. The assumptions of the method prescribe a fully penetrating well (a well open through the full thickness of the aquifer) in a confined, nonleaky aquifer. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|