Standard Test Method for Flash Point by Tag Closed Tester
Automaticky přeložený název:
Standardní zkušební metoda pro Bod vzplanutí podle Tag Closed Tester
NORMA vydána dne 10.8.2000
Označení normy: ASTM D56-01
Poznámka: NEPLATNÁ
Datum vydání normy: 10.8.2000
Kód zboží: NS-31824
Počet stran: 11
Přibližná hmotnost: 33 g (0.07 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
combustible, fire risk, flammable, flash point, tag closed cup, ICS Number Code 87.040 (Paints and varnishes)
| 1. Scope | ||||||||||||||||||||||||||||||
|
1.1 This test method covers the determination of the flash point, by tag manual and automated closed testers, of liquids with a viscosity below 5.5 mm2/s (cSt) at 40oC (104oF), or below 9.5 mm2/s (cSt) at 25oC (77oF), and a flash point below 93oC (200oF). 1.1.1 For the closed-cup flash point of liquids with the following properties: a viscosity of 5.5 mm2/s (cSt) or more at 40oC (104oF); a viscosity of 9.5 mm2/s (cSt) or more at 25oC (77oF); a flash point of 93oC (200oF) or higher; a tendency to form a surface film under test conditions; or containing suspended solids, Test Method D93 can be used. 1.1.2 For cut-back asphalts refer to Test Methods D1310 and D3143. Note 1--The U.S. Department of Transportation (RSTA) and U.S. Department of Labor (OSHA) have established that liquids with a flash point under 37.8oC (100oF) are flammable as determined by this test method for those liquids that have a viscosity less than 5.5 mm2/s (cSt) at 40oC (104oF) or 9.5 mm2/s (cSt) or less at 25oC (77oF), or do not contain suspended solids or do not have a tendency to form a surface film while under test. Other flash point classifications have been established by these departments for liquids using this test method. 1.2 This test method can be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and cannot be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test method can be used as elements of fire risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. 1.3 Related Standards are Test Methods D93, D1310, D3828, D3278, and D3941. 1.4 The values stated in SI units are to be regarded as standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see 8.2 and 8.3 and refer to Material Safety Data Sheets. |
||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 28.08.2026 (Počet položek: 2 298 625)
© Copyright 2026 NORMSERVIS s.r.o.