Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determining Activity and Selectivity of Fluid Catalytic Cracking (FCC) Catalysts by Microactivity Test
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení aktivity a selektivita fluidního katalytického krakování ( FCC ) katalyzátory podle Microactivity testu
NORMA vydána dne 1.10.2005
Označení normy: ASTM D5154-05
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2005
Kód zboží: NS-30053
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
catalysts, FCC, Fluid cracking catalyst, MAT, microactivity, selectivity
| Significance and Use | ||||||||||||||
|
The microactivity test provides data to assess the relative performance of FCC catalysts. Because results are affected by catalyst pretreatment, feedstock characteristics, test equipment, and operating parameters, adherence to this test method is a prerequisite for correct interpretation of results. Apparatus, test conditions, and analytical procedures actually used should closely resemble those described in this test method. Significant variations in apparatus, test conditions and/or analytical procedures may result in activity and selectivity data which do not correlate with data developed by other laboratories on identical catalyst/feedstock samples. The standard method reaction temperature is 516°C (960°F). Other reaction temperatures can be used; however, catalyst selectivity data developed at temperatures other than 516°C may not correlate with selectivity data developed at 516°C. Also, precision at other reaction temperatures may change compared to data obtained at 516°C. |
||||||||||||||
| 1. Scope | ||||||||||||||
|
1.1 This test method covers determining the activity and selectivity of either equilibrium or laboratory deactivated fluid catalytic cracking (FCC) catalysts. The activity is evaluated on the basis of weight percent conversion of gas oil in a microactivity unit. The selectivities are evaluated on the basis of weight percent yields of specifically defined products resulting from the catalytic cracking of gas oil. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are provided for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
| 2. Referenced Documents | ||||||||||||||
|
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.09.2026 (Počet položek: 2 300 131)
© Copyright 2026 NORMSERVIS s.r.o.