Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Inhibition of Respiration in Microbial Cultures in the Activated Sludge Process (Includes all amendments And changes 8/16/2017).
Automaticky přeložený název:
Standardní zkušební metoda pro inhibici dýchání v mikrobiální kultury v procesu aktivovaného kalu
NORMA vydána dne 1.1.1995
Označení normy: ASTM D5120-90(1995)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.1995
Kód zboží: NS-29914
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
ctivated sludge, inhibition of respiration-microbial cultures in the activated sludge, process, test, , Antimicrobial formulations, inhibition of respiration-microbial cultures in the activated sludge, process, test, , Batch procedures, inhibition of respiration-microbial cultures in the activated sludge, process, test, , Inhibition, inhibition of respiration-microbial cultures in the activated sludge, process, test, , Microbiological examination
1. Scope | ||
1.1 This test method covers a batch procedure that evaluates the impact of selected wastewaters, materials, or specific compounds on the respiration rate of an aqueous microbial culture, such as activated sludge. 1.2 Alternative procedures for measurement of microbial activity, such as adenosine 5` triphosphate (ATP), specific substrate utilization, etc. are not within the scope of this test method. 1.3 The results obtained are based on comparisons in a specific test series that examines a range of concentrations of the potentially inhibitory test candidate using batch methods in a laboratory. Results are completed in a short time frame (a few hours). 1.4 The test results are specific to the microbial culture used. Microbial culture from different wastewater treatment plants will differ in kinds and numbers of organisms, and performance capability. Thus, there is no basis for comparing results for microbial cultures from different treatment facilities. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 23.12.2024 (Počet položek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.