Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determining the Unreacted Monomer Content of Latexes Using Capillary Column Gas Chromatography
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení nezreagovaného monomeru Obsah Latexy pomocí kapilární plynové chromatografie
NORMA vydána dne 1.2.2009
Označení normy: ASTM D4827-03(2009)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.2.2009
Kód zboží: NS-28786
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
gas chromatography, gas chromatography (capillary column), latex paints, latex vehicles, monomer (unreacted), unreacted monomer content, Calibration--paints/related coatings analysis instrumentation, Gas chromatography (GC)--paints/related coatings/materials, n-Butylacrylate, n-Butyl methacrylate, Capillary gas chromatography, Latex paints, Latex vehicles, Methyl methacrylate plastics, Monomr content, Styrene, Unreacted monomer content
| Significance and Use | ||
|
Excessive amounts of unreacted monomer may cause concerns relating to toxicity and odor. This test method is designed to measure the unreacted monomer content of latexes. The results may be used to monitor the extent of polymerization during manufacture, as well as to establish maximum unreacted monomer content for regulatory purposes. |
||
| 1. Scope | ||
|
1.1 This test method is for the determination of the unreacted monomer content of acrylic latexes. Monomers that have been successfully determined by this procedure include n-butyl methacrylate, n-butyl acrylate, styrene, and methyl methacrylate. The determination of other monomers has not been evaluated, but this test method is believed to be applicable. The established working range of this test method is from 100 to 1000 μ g/g, but there is no reason to believe it will not work outside of this range, provided that appropriate dilutions and adjustments in specimen size are made. 1.2 The unreacted monomer in acrylic latexes is expected to change with time and environmental factors. This time dependence of the determination may be seen as an artificially large deviation of results, making the test method mostly applicable for in-house quality control, where sampling and analysis conditions can be better controlled. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7. |
||
| 2. Referenced Documents | ||
|
Poslední aktualizace: 09.09.2026 (Počet položek: 2 300 143)
© Copyright 2026 NORMSERVIS s.r.o.