Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Vinyl Chloride in Workplace Atmospheres (Charcoal Tube Method)
Automaticky přeložený název:
Standardní zkušební metoda pro vinylchloridu v ovzduší na pracovišti (Charcoal metoda Tube)
NORMA vydána dne 1.9.2014
Označení normy: ASTM D4766-98(2014)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.9.2014
Kód zboží: NS-28487
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
air monitoring, charcoal tube method, sampling and analysis, vinyl chloride, workplace atmosphere, ICS Number Code 13.040.30 (Workplace atmospheres)
Significance and Use | ||||||
5.1 Vinyl chloride monomer (VCM) is the starting material for the manufacture of poly(vinyl chloride) (PVC), which is used extensively in construction, electronics, packaging, and other industries. The vinyl chloride gas can escape during manufacturing, transportation, and polymerization stages. Residual monomer can also escape during subsequent fabrication processes. 5.2 Vinyl chloride is a toxic and explosive hazardous material. 5.3 Vinyl chloride is suspected to be a carcinogenic agent 5.4 The method is made selective for vinyl chloride by choosing chromatograph columns that will separate vinyl chloride from other organic compounds in the sample. 5.5 The method meets requirements (for example, those of OSHA) for monitoring workplace atmospheres in vinyl chloride and poly(vinyl chloride) production and fabrication processes. |
||||||
1. Scope | ||||||
1.1 This test method describes the determination of vinyl chloride monomer (VCM) in workplace atmospheres using a modified charcoal tube method (see Practice D3686). 1.2 This procedure is compatible with low flow rate personal sampling equipment. It can be used for personal or stationary monitoring. It cannot determine instantaneous fluctuations in concentration to detect maximum values. Alternative on-site procedures, such as gas chromatography or infrared spectrometry, must be used to measure fast-changing concentrations. 1.3 The range of this test method is from the limit of detection of approximately 0.01 to 100 ppm (v). 1.4 The sampling method provides a time-weighted average sample. 1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For more specific precautionary statements, see Section 9 and Warnings in 10.2.3 and 11.1.3. |
||||||
2. Referenced Documents | ||||||
|
Historická
15.9.2011
Historická
1.3.2005
Historická
1.4.2008
Historická
1.4.2010
Historická
1.4.2013
Historická
1.4.2013
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.