Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Single-Point Determination of Specific Surface Area of Catalysts and Catalyst Carriers Using Nitrogen Adsorption by Continuous Flow Method
Automaticky přeložený název:
Standardní zkušební metoda pro jednobodové Stanovení měrného povrchu katalyzátorů a nosičů katalyzátoru Použití adsorpcí dusíku podle Continuous Method Flow
NORMA vydána dne 1.4.2008
Označení normy: ASTM D4567-03(2008)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2008
Kód zboží: NS-27729
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
adsorption, catalyst carriers, catalysts, continuous flow, surface area, Automated procedures--petroleum products analysis, BET (Brunauer, Emmett, and Teller) surface area, Catalysts/catalyst carriers, Continuous flow method, Flow and flow rate--petroleum products, Isotherm techniques, Nitrogen adsorption surface area, Single-point surface area, Surface analysis--catalysts, ICS Number Code 71.040.30 (Chemical reagents)
| Significance and Use | ||||||||||
|
This test method is useful for determining the specific surface area of catalysts and catalyst carriers for material specifications, manufacturing control, and research and development in the evaluation of catalysts. |
||||||||||
| 1. Scope | ||||||||||
|
1.1 This test method covers the single-point determination of the surface area of catalysts and catalyst carriers that exhibit Type II or Type IV nitrogen adsorption isotherms using a nitrogen-helium flowing gas mixture. This test method is applicable for the determination of total surface areas from 0.1 to 300 m2, where rapid surface area determinations are desired. 1.2 Because the single-point method uses an approximation of the BET equation, the multipoint BET method (Test Method D 3663) is preferred to the single-point method. Note 1—This is particularly true when testing microporous materials. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
| 2. Referenced Documents | ||||||||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 04.09.2026 (Počet položek: 2 300 131)
© Copyright 2026 NORMSERVIS s.r.o.