Standard Test Method for Particle Size Distribution of Catalytic Material by Laser Light Scattering
Automaticky přeložený název:
Standardní zkušební metoda pro Distribuce velikosti částic katalytického materiálu pomocí rozptylu laserového světla
NORMA vydána dne 1.10.2005
Označení normy: ASTM D4464-00(2005)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2005
Kód zboží: NS-27337
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
catalyst, Fraunhofer Diffraction, light scattering, Mie Scattering, ICS Number Code 19.120 (Particle size analysis. Sieving)
| Significance and Use | ||||||||||||
|
It is important to recognize that the results obtained by this test method or any other method for particle size determination utilizing different physical principles may disagree. The results are strongly influenced by physical principles employed by each method of particle size analysis. The results of any particle sizing method should be used only in a relative sense and should not be regarded as absolute when comparing results obtained by other methods. Light scattering theories (Fraunhofer Diffraction3 and Mie Scattering4 ) that are used for determination of particle size has been available for many years. Several manufacturers of testing equipment now have units based on these principles. Although each type of testing equipment utilizes the same basic principles for light scattering as a function of particle size, different assumptions pertinent to application of the theory and different models for converting light measurements to particle size, may lead to different results for each instrument. Furthermore, any particles which are outside the size measurement range of the instrument will be ignored, causing an increase in the reported percentages within the detectable range. A particle size distribution which ends abruptly at the detection limit of the instrument may indicate that particles outside the range are present. Therefore, use of this test method cannot guarantee directly comparable results from different types of instruments. This test method can be used to determine particle size distributions of catalysts and supports for materials specifications, manufacturing control, and research and development work. |
||||||||||||
| 1. Scope | ||||||||||||
|
1.1 This test method covers the determination of the particle size distribution of catalyst and catalyst carrier particles and is one of several found valuable for the measurement of particle size. The range of particle sizes investigated was 30 to 300 μm equivalent spherical diameter. The technique is capable of measuring particles above and below this range. The angle and intensity of laser light scattered by the particles are selectively measured to permit calculation of a volume distribution using light-scattering techniques. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 03.09.2026 (Počet položek: 2 300 115)
© Copyright 2026 NORMSERVIS s.r.o.