Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Elements in Water by Direct-Current Argon Plasma Atomic Emission Spectroscopy
Automaticky přeložený název:
Standardní zkušební metoda pro prvky ve vodě stejnosměrný Argon Plasma atomové emisní spektroskopie
NORMA vydána dne 1.10.2008
Označení normy: ASTM D4190-08
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2008
Kód zboží: NS-26374
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
direct-current plasma, DCP, elements, water, Argon plasma spectrometry/spectroscopy, D-C plasma spectrometers, Dissolved elements (of water), Drinking water, Fresh water, High-purity water, Inorganic compounds--water, Reagent water, Seawater (natural/synthetic), Total recoverable elements (in water), ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This test method is useful for the determination of element concentrations in many natural waters. It has the capability for the simultaneous determination of up to 15 separate elements. High analysis sensitivity can be achieved for some elements, such as boron and vanadium. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This test method covers the determination of dissolved and total recoverable elements in water, which includes drinking water, lake water, river water, sea water, snow, and Type II reagent water by direct current plasma atomic emission spectroscopy (DCP). 1.2 The information on precision and bias may not apply to other waters. 1.3 This test method is applicable to the 15 elements listed in Annex A1 (Table A1.1) and covers the ranges in Table 1. 1.4 This test method is not applicable to brines unless the sample matrix can be matched or the sample can be diluted by a factor of 200 up to 500 and still maintain the analyte concentration above the detection limit. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 Solutions for Analysis
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Poslední aktualizace: 22.11.2024 (Počet položek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.