Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Theis Nonequilibrium Method
Automaticky přeložený název:
Standardní zkušební metoda pro ( analytický postup ) pro určování Transmisivita a skladování Koeficient Nonleaky Napjaté kolektory podle Theis Nerovnovážná metody
NORMA vydána dne 15.4.2015
Označení normy: ASTM D4106-15
Poznámka: NEPLATNÁ
Datum vydání normy: 15.4.2015
Kód zboží: NS-591120
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
aquifer tests, aquifers, control wells, groundwater, hydraulic conductivity, observation wells, storage coefficient, transmissivity,, ICS Number Code 93.160 (Hydraulic construction)
Significance and Use | ||
5.1 Assumptions: 5.1.1 Well discharges at a constant rate, 5.1.2 Well is of infinitesimal diameter and fully penetrates the aquifer. 5.1.3 The nonleaky aquifer is homogeneous, isotropic, and aerially extensive. A nonleaky aquifer receives insignificant contribution of water from confining beds. 5.1.4 Discharge from the well is derived exclusively from storage in the aquifer. 5.1.5 The geometry of the assumed aquifer and well conditions are shown in Fig. 1. |
||
Sy | = | the specific yield. For fully penetrating observation wells, the effects of delayed yield are negligible at the distance, r, in Eq 8 after one tenth of the time given in the Eq 9. |
1. Scope | ||||||||||
1.1 This test method covers an analytical procedure for determining the transmissivity and storage coefficient of a nonleaky confined aquifer. It is used to analyze data on water-level response collected during radial flow to or from a well of constant discharge or injection. 1.2 This analytical procedure, along with others, is used in conjunction with the field procedure given in Test Method D4050. 1.3 Limitations—The limitations of this test method for determination of hydraulic properties of aquifers are primarily related to the correspondence between the field situation and the simplifying assumptions of this test method (see 5.1). 1.4 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. 1.4.1 The procedures used to specify how data are collected/recorded or calculated, in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 17.05.2024 (Počet položek: 2 902 148)
© Copyright 2024 NORMSERVIS s.r.o.