Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Barium in Brines, Seawater, and Brackish Water by Direct-Current Argon Plasma Atomic Emission Spectroscopy
Automaticky přeložený název:
Standardní zkušební metoda pro Barium v solanky, mořské vodě, a brakické vody pomocí stejnosměrného proudu argonu plazmatu atomové emisní spektroskopie
NORMA vydána dne 1.9.2011
Označení normy: ASTM D3986-11
Poznámka: NEPLATNÁ
Datum vydání normy: 1.9.2011
Kód zboží: NS-25611
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
barium, brackish water, brines, direct-current argon plasma atomic emission, seawater, spectroscopy, Argon plasma spectrometry/spectroscopy, Barium content--water, Brackish water/brines, D-C plasma spectrometers, Inorganic compounds--water, Seawater (natural/synthetic), ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | ||||||||||||
All waters containing acid soluble barium compounds are known to be toxic. This test method is useful for the determination of barium in brines, seawater, and brackish waters. Consumption, inhalation, or absorption of 500 to 600 mg of barium is considered fatal to human beings. Lower levels may result in disorders of the heart, blood vessels, and nerves. The drinking water standards set the maximum contaminant level for barium as 2 mg/L barium. |
||||||||||||
1. Scope | ||||||||||||
1.1 This test method covers the determination of dissolved and total recoverable barium in brines, seawater, and brackish waters by direct-current argon plasma atomic emission spectroscopy (DCP–AES). 1.2 This test method has been tested in the range from 10 mg/L to 20 mg/L. Samples shall be diluted to contain concentrations within the calibration range (see 11.1 and 12.5). Higher concentrations can also be determined by changing to a less sensitive emission line. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Historická
1.9.2012
Historická
1.9.2012
Historická
15.6.2012
Historická
1.10.2008
Historická
1.10.2009
Historická
1.1.2013
Poslední aktualizace: 23.12.2024 (Počet položek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.