Standard Practices for Detecting Leaks in Reverse Osmosis Devices (Includes all amendments And changes 12/31/2010).
Automaticky přeložený název:
Standardní postupy pro detekci netěsností v Reverzní osmóza zařízení
NORMA vydána dne 10.6.2003
Označení normy: ASTM D3923-94(2003)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 10.6.2003
Kód zboží: NS-25355
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
dye test, leaks, O-ring test, reverse osmosis, tubesheet leak test, vacuum test, ICS Number Code 71.120.99 (Other equipment for the chemical industry)
| Significance and Use | ||||||||||||||
|
These practices may be used to determine whether a reverse-osmosis device is free of leaks if the mechanical integrity of the device is to be confirmed. They may also be used to detect leaks in reverse-osmosis devices whose operating performance indicates a possible leak. These practices may be used for either new or used devices. |
||||||||||||||
| 1. Scope | ||||||||||||||
|
1.1 These practices cover detecting leaks in which there is a direct communication between the feed or concentrate, or both, and the permeate. Several types of leaks are possible with the various configurations of reverse-osmosis devices. 1.2 Types of Leaks 1.2.1 With hollow-fiber devices, feed or concentrate leakage, or both, into the permeate stream by leaks through the tube sheet and past the tube sheet O-ring are possible. "Leaks" caused by broken fibers are not covered by these practices. 1.2.2 With spiral-wound devices, leaks may occur through damage of the membrane surface itself by punctures or scratches, by glue-line failure, and by O-ring leaks on product tube interconnectors. 1.2.3 With tubular devices, leaks due to membrane damage, tube end seal leaks, and leaks from broken tubes or product headers are possible. 1.3 Three leak test practices are given as follows:
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
| 2. Referenced Documents | ||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 26.08.2026 (Počet položek: 2 298 418)
© Copyright 2026 NORMSERVIS s.r.o.