Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape
Automaticky přeložený název:
Standardní zkušební metoda pro Adheze citlivých na tlak pásky
NORMA vydána dne 1.4.2010
Označení normy: ASTM D3330/D3330M-04(2010)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2010
Kód zboží: NS-23308
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
adhesion to backing, adhesion to liner, peel adhesion at 90° angle, peel adhesion at 180° angle, pressure sensitive tape, Adherence, Acceptance criteria/testing, Adhesion--pressure-sensitive tapes, Bond strength--adhesives, Displacement, Double-coated pressure-sensitive tape, Loading tests--pressure-sensitive tapes, Packing/packaging materials/systems (pressure-sensitive tape), Fiberboard containers, Peel adhesion, Pressure-sensitive tapes, Single-coated pressure-sensitive tape, Steel surfaces
Significance and Use | ||||||||||||||||||
These test methods are tools for quality assurance use. Given specific pressure-sensitive tape and a requirement in terms of the minimum or maximum peel value expected for this tape, the data from the test can be used in conjunction with acceptance criteria. Test Method A, B, C, E, or F can show the relative bond strength of a given tape to one or more surfaces (material and texture) as compared to the standard stainless steel panel. Substitution of representative samples of materials in question for the standard steel panel would suffice to do this. Test Methods A, B, C, E or F cannot be used to compare two pressure-sensitive tapes of the same type but of different manufacture for their ability to adhere to a surface. This is because the measured peel force is not normalized for a fixed area of stress. The area under stress varies with backing stiffness and adhesive rheology (firmness). Two different tapes seldom agree in these properties. Test Method D can show the amount of force required to remove a liner that covers the adhesive side of a tape at a specified peel rate. The force will be different at other peel rates. These test methods may not provide design information as there is usually no direct relationship between peel adhesion and any functional requirement. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 These test methods cover the measurement of the peel adhesion of pressure-sensitive tapes. 1.1.1 Test Method A gives a measure of the adherence, when peeled at 180° angle, to a standard steel panel or to other surface of interest for a single-coated tape. 1.1.2 Test Method B gives a measure of the adherence to the backing of a single-coated tape. 1.1.3 Test Method C gives a measure of the adherence of double-coated tape to a standard steel panel or other surface of interest. 1.1.4 Test Method D gives a measure of the adherence of the release liner to the adhesive of either single- or double-coated tape. 1.1.5 Test Method E gives a measure of the adherence of an adhesive transfer tape to a standard steel panel or other surface of interest. 1.1.6 Test Method F gives a measure of the adherence, when peeled at 90° angle, to a standard steel panel or other surface of interest for a single-coated tape. 1.2 These test methods provide a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive adhesive tape. The assessment may be within a roll of tape, between rolls, or between production lots. 1.3 Variations in either the tape backing or the adhesive, or both, affect the response. Therefore, these test methods cannot be used to pinpoint the specific cause(s) of non-uniformity. 1.4 These test methods may not be appropriate to test tapes having relatively stiff backings, stiff liners, or backings showing high stretch at low forces. These characteristics will result in a high variability for the test response which is not a true indication of the real nature of the adhesive bond. 1.5 Values stated in either SI or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents, therefore, each system must be used independently without combining values in any way. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historická
1.5.2007
Historická
1.3.2014
Historická
1.7.2013
Historická
1.10.2013
Historická
1.10.2012
Historická
1.10.2012
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)